Safeties Overview
Safety devices
The table below contains an overview of the safety devices.
(1)
: An overview of the fuses and overcurrent relays is given in "Checking the Power Supply and Fuses"
Alarm
description
Alarm
indication
Activation
Reset
Wiring code
Device
Flow switch or
pump contact
fl
No flow for 5 s or no sufficient flow
during a period of 15 s after pump
start.
Manual software
reset
S10L, S11L
Contact closed
on flow
Reverse phase
protector
fl h1
Imbalance or reversed or no power
supply
Correct phase
sequence, switch
power back ON
R1P, K4A
Contact
ON/OFF
High-pressure
switch
h1
Discharge pressure
> 30.9 bar
Manual software
reset
S1PH
Switch ON/OFF
Low-pressure
switch
l1
Low-pressure ON
■
Standard: 2.0 bar ± 0.3
■
ZL/ZH: 1.5 bar ± 0.3
Manual software
reset
S4LP
Switch ON/OFF
Outlet water
temp. too low
(freeze-up
protection)
a1
Outlet water temp.
■
temp. < 2.5°C
■
temp. < -11.5 °C
■
temp. < -6.5 °C
Standard
ZL option
ZH option
Manual software
reset
R4T
NTC sensor
Discharge ther-
mal protector
h1
Compressor discharge temp.
> 135°C
Manual software
reset and temp.
< 115°C
Q1D
Bimetal
ON/OFF
Overcurrent
relay
h1
Overcurrent
(1)
Manual software
reset
K4S
Bimetal
ON/OFF
NTC probe of
the inlet water
temperature
evaporator
e1
Probe is defective
Automatic reset
R3T
NTC sensor
NTC probe of
the outlet water
temperature
evaporator
e2
Probe is defective
Automatic reset
R4T
NTC sensor
NTC probe of
the inlet water
temperature
condenser
e3
Probe is defective
Automatic reset
R5T
NTC sensor
EEPROM on
the controller
PCB
ee ep
EEPROM is defective
Automatic reset
—
Controller
Summary of Contents for EUWL KZW1 Series
Page 1: ......
Page 2: ......
Page 8: ...Introduction ESIE 0303 vi 3 1 4 5 ...
Page 10: ...ESIE 0303 1 2 Part 1 System Outline 3 1 1 5 ...
Page 50: ...Piping Layout ESIE 0303 1 42 Part 1 System Outline 3 1 1 4 5 ...
Page 60: ...Wiring Layout ESIE 0303 1 52 Part 1 System Outline 3 1 1 4 5 ...
Page 61: ...ESIE 0302 Wiring Layout Part 1 System Outline 1 53 3 6 Wiring Diagram Wiring diagram ...
Page 62: ...Wiring Layout ESIE 0302 1 54 Part 1 System Outline ...
Page 64: ...ESIE 0303 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 84: ...ESIE 0303 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 87: ...ESIE 0303 Inputs and Outputs Overview Part 3 Troubleshooting 3 5 3 3 4 5 1 ...
Page 88: ...Inputs and Outputs Overview ESIE 0303 3 6 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 94: ...Malfunction Indications and Safeties Overview ESIE 0303 3 12 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 100: ...Checking the Inputs and Outputs ESIE 0303 3 18 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 112: ...Troubleshooting ESIE 0303 3 30 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 114: ...ESIE 0303 4 2 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 130: ...ESIE 0303 5 2 Part 5 Maintenance 3 1 5 ...
Page 139: ...ESIE 0303 Index 3 3 4 5 1 Wiring Diagram k 1 53 ...
Page 140: ...ESIE 0303 4 Index 3 1 4 5 ...