2/14
Breadcrumb
Setting name
Range, step
Default value
Date
Value
Room
└─
Antifrost
1.4.1
[2-06]
R/W
0: No
1: Yes
1.4.2
[2-05]
R/W
4~16°C, step: 1°C
12°C
└─
Setpoint range
1.5.1
[3-07]
R/W
12~18°C, step: 1°C
12°C
1.5.2
[3-06]
R/W
18~30°C, step: 1°C
30°C
1.5.3
[3-09]
R/W
15~25°C, step: 1°C
15°C
1.5.4
[3-08]
R/W
25~35°C, step: 1°C
35°C
Room
1.6
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
1.7
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
└─
Room comfort setpoint
1.9.1
[9-0A]
R/W
[3-07]
~
[3-06]°C, step: 0,5°C
23°C
1.9.2
[9-0B]
R/W
[3-09]
~
[3-08]°C, step: 0,5°C
23°C
Main zone
2.4
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
└─
Heating WD curve
2.5
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
2.5
[1-01]
R/W
10~25°C, step: 1°C
15°C
2.5
[1-02]
R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0
35°C
[2-0C]=1
45°C
[2-0C]=2
60°C
2.5
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
[2-0C]=0
25°C
[2-0C]=1
35°C
[2-0C]=2
40°C
└─
Cooling WD curve
2.6
[1-06]
R/W
10~25°C, step: 1°C
20°C
2.6
[1-07]
R/W
25~43°C, step: 1°C
35°C
2.6
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0
22°C
[2-0C]=1
15°C
[2-0C]=2
22°C
2.6
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0
18°C
[2-0C]=1
7°C
[2-0C]=2
18°C
Main zone
2.7
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
└─
Setpoint range
2.8.1
[9-01]
R/W
15~37°C, step: 1°C
25°C
2.8.2
[9-00]
R/W ([2-
0C]
≠
2)
R/O ([2-
0C] = 2)
[2-0C]=2:
37~70, step: 1°C
65°C
[2-0C]
≠
2:
37~55, step: 1°C
55°C
2.8.3
[9-03]
R/W
5~18°C, step: 1°C
5°C
2.8.4
[9-02]
R/W
18~22°C, step: 1°C
22°C
Main zone
2.9
[C-07]
R/W
0: Leaving water
1: External room thermostat
2: Room thermostat
2.A
[C-05]
R/W
1: 1 contact
2: 2 contacts
└─
Delta T
2.B.1
[1-0B]
R/W ([2-
0C]
≠
2)
R/O ([2-
0C] = 2)
3~10°C, step: 1°C
[2-0C]
≠
2 (Radiator)
5°C
[2-0C] = 2 (Radiator)
10°C
2.B.2
[1-0D]
R/W
3~10°C, step: 1°C
5°C
Cooling minimum
Cooling maximum
Room sensor offset
Room sensor offset
Setpoint mode
Low ambient temp. for LWT main zone heating WD curve.
Heating comfort setpoint
Field settings table
Installer setting at variance with
default value
Activation
Room setpoint
Heating minimum
Heating maximum
Cooling minimum
Cooling maximum
Control
Heating minimum
Emitter type
Heating maximum
Leaving water value for high ambient temp. for LWT main zone
cooling WD curve.
Cooling comfort setpoint
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone
cooling WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone
heating WD curve.
Low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone
heating WD curve.
Ext Thermostat type
Delta T heating
Delta T cooling
4P685235-1 - 2022.03