![background image](http://html1.mh-extra.com/html/daikin/drc036/drc036_installation-instructions-manual_3389104017.webp)
17
APPENDIX A BLOWER PERFORMANCE TABLES - AC
3 Ton Cooler
Standard Static Drive
Models: DRC0361D and DRC0363D
Down Flow
Horizontal Flow
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
T1
0.2
978
525 0.04
T1
0.2
998
558 0.04
0.4
-
-
-
0.4
-
-
-
0.6
-
-
-
0.6
-
-
-
0.8
-
-
-
0.8
-
-
-
1.0
-
-
-
1.0
-
-
-
T2
0.2
1269 568 0.18
T2
0.2
1295 643 0.21
0.4
1176 621 0.20
0.4
1200 702 0.23
0.6
1084 696 0.22
0.6
1106 776 0.25
0.8
991
760 0.24
0.8
1011 851 0.27
1.0
898
828 0.27
1.0
916
901 0.29
T3
0.2
1115 568 0.15
T3
0.2
1138 604 0.16
0.4
1095 620 0.17
0.4
1117 660 0.18
0.6
1004 695 0.19
0.6
1024 739 0.20
0.8
899
760 0.21
0.8
917
808 0.22
1.0
770
827 0.22
1.0
786
880 0.24
T4
0.2
1365 640 0.23
T4
0.2
1393 681 0.24
0.4
1262 698 0.25
0.4
1288 743 0.27
0.6
1166 763 0.27
0.6
1190 812 0.29
0.8
1034 839 0.30
0.8
1055 893 0.32
1.0
995
867 0.31
1.0
1015 922 0.33
T5
0.2
-
-
-
T5
0.2
-
-
-
0.4
1378 756 0.32
0.4
1406 804 0.34
0.6
1291 816 0.35
0.6
1317 868 0.37
0.8
1197 873 0.37
0.8
1221 929 0.40
1.0
1078 938 0.40
1.0
1100 998 0.43
Shaded area indicates air flow below 1200 SCFM (300 SCFM/ton)
that is not recommended for High Stage cooling or heating
3 Ton Cooler
Standard Static Drive
Models: DRC0364D and DRC0367D
Down Flow
Horizontal Flow
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
T1
0.2
940
533 0.11
T1
0.2
961
540 0.11
0.4
729
642 0.13
0.4
751
654 0.13
0.6
562
735 0.15
0.6
589
740 0.15
0.8
396
765 0.15
0.8
404
813 0.16
1.0
-
-
-
1.0
-
-
-
T2
0.2
1488 685 0.28
T2
0.2
-
-
-
0.4
1374 751 0.30
0.4
1387 759 0.31
0.6
1233 843 0.34
0.6
1262 837 0.34
0.8
1072 914 0.37
0.8
1105 919 0.37
1.0
950
974 0.39
1.0
998
976 0.39
T3
0.2
1216 609 0.18
T3
0.2
1237 614 0.18
0.4
1065 708 0.21
0.4
1095 704 0.21
0.6
906
784 0.23
0.6
924
794 0.24
0.8
766
854 0.25
0.8
792
863 0.26
1.0
627
882 0.26
1.0
640
937 0.28
T4
0.2
1488 685 0.28
T4
0.2
-
-
-
0.4
1374 751 0.30
0.4
1387 759 0.31
0.6
1233 843 0.34
0.6
1262 837 0.34
0.8
1072 914 0.37
0.8
1105 919 0.37
1.0
950
974 0.39
1.0
998
976 0.39
T5
0.2
-
-
-
T5
0.2
-
-
-
0.4
1490 782 0.36
0.4
-
-
-
0.6
1369 859 0.40
0.6
1401 860 0.40
0.8
1220 934 0.43
0.8
1252 944 0.44
1.0
1102 992 0.46
1.0
1120 1006 0.47
Shaded area indicates air flow below 1200 SCFM (300 SCFM/ton)
that is not recommended for High Stage cooling or heating