APPENDIX A BLOWER PERFORMANCE TABLES - HEAT PUMP
6 Ton Heat Pump
Standard Static Drive
Models: DRH0723D, DRH0724D and DRH0727D
Down Flow
Horizontal Flow
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
SPEED
TAP
EXTERNAL
STATIC
PRESSURE
(ESP),
IN WC
SCFM RPM BHP
T1
0.2
1394 635 0.21
T1
0.2
1382
642 0.21
0.4
1265 711 0.24
0.4
1259
724 0.24
0.6
1127 805 0.27
0.6
1160
799 0.27
0.8
983
885 0.29
0.8
1016
879 0.29
1.0
855
952 0.32
1.0
899
948 0.32
T2
0.2
2301 832 0.77
T2
0.2
2348
926 0.86
0.4
2229 882 0.82
0.4
2274
973 0.90
0.6
2156 929 0.86
0.6
2200 1020 0.95
0.8
2083 979 0.91
0.8
2126 1066 0.99
1.0
2011 1033 0.96
1.0
2052 1113 1.03
T3
0.2
2226 892 0.69
T3
0.2
2211
885 0.68
0.4
2143 931 0.72
0.4
2128
938 0.73
0.6
2052 973 0.75
0.6
2034
988 0.76
0.8
1950 1027 0.79
0.8
1950 1042 0.81
1.0
1861 1080 0.84
1.0
1859 1098 0.85
T4
0.2
2301 903 0.84
T4
0.2
2348
926 0.86
0.4
2229 935 0.87
0.4
2274
973 0.90
0.6
2156 987 0.92
0.6
2200 1020 0.95
0.8
2083 1034 0.96
0.8
2126 1066 0.99
1.0
2011 1080 1.00
1.0
2052 1113 1.03
T5
0.2
2435 972 0.93
T5
0.2
2404
961 0.91
0.4
2362 1007 0.96
0.4
2347
995 0.95
0.6
2293 1043 0.99
0.6
2273 1050 1.00
0.8
2209 1086 1.03
0.8
2193 1100 1.05
1.0
2124 1134 1.08
1.0
2111 1149 1.09
Shaded area indicates air flow below 1800 SCFM (300 SCFM/ton) that
is not recommended for High Stage cooling or heating