background image

English 

BYCQ140CGW1

Self Cleaning decoration panel

 Installation 

manual

CONTENTS

1. SAFETY 

PRECAUTIONS 

..........................................................1

2. ACCESSORY.............................................................................1

3. INSTALLATION 

SITE 

.................................................................2

4.  PREPARATIONS FOR PANEL...................................................3

5.  PREPARATIONS FOR INDOOR UNIT ......................................4

6.  ATTACHING PANEL TO INDOOR UNIT ....................................5

7.  ATTACHING SUCTION GRILLE 

AND DECORATION CORNER COVERS ..................................7

8.  OPERATION MODE SETTINGS .............................................10

9. FIELD 

SETTINGS 

....................................................................10

10. TEST OPERATION ..................................................................10

SAFETY PRECAUTIONS

1. 

Please read these “SAFETY PRECAUTIONS” carefully before 
installing air conditioning equipment and be sure to install it correctly.
After completing installation, conduct a trial operation to check for 
faults and explain to the customer how to operate the air condi-
tioner and take care of it with the aid of the operation manual. Ask 
the customer to store the installation manual along with the 
operation manual for future reference.

This air conditioner comes under the term “appliances not 
accessible to the general public”.

Meaning of WARNING and CAUTION notices.

WARNING

Failure to follow these instructions properly 
may result in personal injury or loss of life. 

CAUTION

Failure to observe these instructions properly 
may result in property damage or personal 
injury, which may be serious depending on 
the circumstances.

 WARNING

Ask your dealer or qualifi ed personnel to carry out installation 

• 

work. 
Do not attempt to install the air conditioner yourself. Improper 
installation may result in water leakage, electric shocks or fi re.
Perform installation work in accordance with the instructions in 

• 

this installation manual. Do not modify the product. 
Improper installation may result in water leakage, electric shocks, 
or fi re.
Be sure to use only the specifi ed accessories and parts for 

• 

installation work. 
Failure to use the specifi ed parts may result in the unit falling, 
water leakage, electric shocks or fi re. 
Make sure that specifi ed wires are used and that there is no 

• 

strain on the terminal connections or wires. 
Improper connections or securing of wires may result in 
abnormal heat radiation or fi re.
Be sure to switch off the unit before touching any electrical parts.

• 

Arrange the lead wires of the provided harness so that the EL. 

• 

COMPO. BOX lid of the indoor unit will not rise, and attach the lid 
securely. 
Heat radiation, electric shocks, or fi re may result if the EL. 
COMPO. BOX lid is not attached properly.
Tear up and dispose of the plastic bag. 

• 

Children playing with the plastic bag may be suffocated.

 CAUTION

Install the indoor and outdoor units, power cord, remote controller 

• 

wiring, and transmission wiring at least 1m away from TV or radio 
sets. This is for the prevention of TV and radio interference.
(Depending on the incoming signal strength, a distance of 
1 meter may not be suffi cient to eliminate noise.)
Pay the utmost attention to the transportation of the product.

• 

Hold the handles on the package to carry the product.
Do not carry the package with the polypropylene band on the 
package held, which will be dangerous because the polypropyl-
ene band may be deformed. 
Do not touch the fi n of the heat exchanger.

• 

Touching the fi n improperly may result in injury.
Do not turn the product power off immediately after the operation 

• 

of the product comes to a stop. 
Always wait for at least 5 minutes before turning the product 
power off. 
Otherwise, water leakage and malfunctions may result.
Do not install the air conditioner in the following locations: 

• 

Where there is a high concentration of mineral oil spray or 

1. 

vapour (e.g. a kitchen). 
Plastic parts will deteriorate, parts may fall off and water 
leakage could result. 
Where corrosive gas, such as sulphurous acid gas, is 

2. 

produced. 
Corroding of copper pipes or soldered parts may result in 
refrigerant leakage. 
Near machinery emitting electromagnetic radiation. 

3. 

Electromagnetic radiation may disturb the operation of the 
control system and result in a malfunction of the unit. 
Where fl ammable gas may leak, where there is carbon fi bre or 

4. 

ignitable dust suspensions in the air, or where volatile 
fl ammables such as paint thinner or gasoline are handled. 
Operating the unit in such conditions may result in fi re.

[Instructions peculiar to this product]

Do not install the product in the following places.
Oil, cigarette tar, and steam will result in sticky dust on the fi lter, 
which may not be cleaned properly. Furthermore, sticky dust may 
cause malfunctions.
Places with oily smoke: Restaurants, factories, etc.
Places with excessive cigarette smoke: Smoking room, etc.
Places with excessive moisture or steam: Restaurants, factories, 
etc.

The air conditioner is not intended for use in a potentially 

• 

explosive atmosphere.

Note

Have the customer actually operate the air conditioner while 

• 

referring to the operation manual and explain the right operation 
of the air conditioner with useful tips given.
Refer to the operation manual along with the installation manual 

• 

provided with the indoor unit.
Use the BRC1E51A7 remote controller.

• 

ACCESSORY

2. 

Check that the following accessories provided with the air condi-
tioner are correct in number. See the following illustration, which 
shows where the accessories are kept.

Backside of the protective 
corrugated cardboard

A set of accessories

The accessories are 
on the backside of the 
protective corrugated 
cardboard under 
the suction grille.

Suction grille

01_EN_3P257556-1.indd   1

01_EN_3P257556-1.indd   1

9/3/2009   4:04:41 PM

9/3/2009   4:04:41 PM

Summary of Contents for BYCQ140CGW1

Page 1: ...er Auto Cleaning Function Self Cleaning decoration panel INSTALLATION MANUAL English Installation manual Self Cleaning decoration panel BYCQ140CGW1 00_CV_3P257556 1 indd 1 00_CV_3P257556 1 indd 1 9 2...

Page 2: ...evention of TV and radio interference Depending on the incoming signal strength a distance of 1 meter may not be sufficient to eliminate noise Pay the utmost attention to the transportation of the pro...

Page 3: ...er the connecting pipe and attachment and ask the customer to keep them Point of operation explanation In addition to the general usage of the air conditioner it is necessary to explain the descriptio...

Page 4: ...the backside of the protective corrugated cardboard Protective corrugated cardboard top The accessories are on the backside Protective corrugated cardboard bottom Note Do not impose force on the swin...

Page 5: ...ovided with the indoor unit Attaching spacer accessory 1 5 1 Indoor unit Remove the bypass hole closure material and peel off the 1 seal and holding tape 3 2 Seal 3 Holding tape Indoor unit 1 Screws 2...

Page 6: ...IONS FOR INDOOR UNIT Furthermore pull out the lead wires disconnected from the corner decoration cover with the display in 4 PREPARA TIONS FOR PANEL from the corner hole carefully so that the lead wir...

Page 7: ...redundant portions of the clamps from their roots after the both ends are secured Tighten the clamps Cut the roots Clamp accessory 5 Return the connected lead wires to the space between the 4 indoor...

Page 8: ...l at the request of the customer Attaching suction grille 7 1 Select either the hook A or B and hook the claws of the suction grille Note The suction grille may be damaged if the wrong hooking side is...

Page 9: ...rds while the suction grill is closed Check that the fall prevention cords do not protrude from the suction grille before closing the suction grille Suction grille Must not protrude Fall prevention co...

Page 10: ...m the suction grille before closing the suction grille Suction grille Must not protrude Fall prevention cord Attaching decoration corner covers 7 4 Connect the decoration corner cover with the display...

Page 11: ...tings TEST OPERATION 10 Perform the test operation of the Self Cleaning decoration panel after the test operation of the indoor unit is finished The test operation of the Self Cleaning decoration pane...

Page 12: ...3P257556 1 EM09A038 0909 HT 00_CV_3P257556 1 indd 2 00_CV_3P257556 1 indd 2 9 2 2009 9 03 28 AM 9 2 2009 9 03 28 AM...

Reviews: