![background image](http://html1.mh-extra.com/html/daikin/bycq140cgw1/bycq140cgw1_installation-manual_2460456006.webp)
5
English
Connect the harness (accessory (4)) to the connectors (X35A
(2)
and X70A) and the three points of the harness on the unit side.
X70A
X35A
Connector
PCB on unit side
Be sure to connect
them securely.
EL. COMPO.
BOX
Harness on the unit side
Harness
(accessory (4))
Glass tube
Note
Make sure that the connectors are securely connected, or
otherwise the swing fl ap, brush unit, or air fi lter will not work.
Attaching EL. COMPO. BOX lid.
5-3
Attach the EL. COMPO. BOX lid in the order opposite to the
procedure in
5-2
(1).
Note
Make sure that the wires or glass tube will not be caught by the EL.
COMPO. BOX lid.
WARNING
Arrange the electric wires neatly and attach the EL. COMPO.
BOX lid securely.
The electric wires being caught or the rising of the EL. COMPO.
BOX lid may result in an electric shock or fi re.
ATTACHING PANEL TO INDOOR UNIT
6.
Install the indoor unit by referring to the installation manual provided
with the indoor unit.
Note
Do not impose force on the swing fl ap, brush unit, or air fi lter when
taking out the panel from the packing material (on the bottom side).
Checks before attaching panel.
6-1
Check the directions of the indoor unit and the engraved marks
•
on the panel as shown below.
The piping block to the PIPING SIDE and the drain socket to the
DRAIN SIDE .
Stand the temporary latching bracket upright.
•
Draw out the lead wires (on the panel side) from the opening.
•
Attaching panel.
6-2
Tentatively put the two temporary latching brackets of the
(1)
suction port of the panel (on the internal circumference side) to
the hooks of the indoor unit.
Note
Leave your hands after confi rming through the check window
that the temporary latching brackets are engaged with the
hooks.
Draw out from the opening the harness attached in “
(2)
5. PREPA-
RATIONS FOR INDOOR UNIT”
.
Furthermore, pull out the lead wires disconnected from the
corner decoration cover (with the display) in “
4. PREPARA-
TIONS FOR PANEL”
from the corner hole carefully so that the
lead wires will not be caught by the mounting bracket.
Put the mounting brackets (in four points) on the corners of the
(3)
panel to the hooks of the circumference of the indoor unit.
(Hook the mounting bracket engraved with the PIPING SIDE
fi rst, followed by the mounting bracket on the opposite angle
side.)
At that time, pay attention that the harness and lead wires (on
the panel side) will not be caught between the panel and
indoor unit.
Note
Leave your hands after confi rming that the mounting brackets
are engaged with the hooks.
Tighten the four hexagon head screws right under the
(4)
mounting bracket for approximately 5mm. (The panel will move
upward.)
Turn the panel in the directions of the arrows so that the
(5)
opening on the ceiling will be perfectly covered by the panel.
Furthermore, tighten the screw (4) until the distance from the
(6)
lower part of the hook of the indoor unit to the lower part of the
panel becomes 107 to 112mm.
Drain
socket
Piping
Hook
Mounting bracket
6-2
(3)
6-2
(1)
6-2
(5)
6-2
(4)
6-2
(6)
Before temporarily
hooking
After temporarily
hooking
Temporary
latching brackets
Check window
Hook
(4 points)
Before hooking
After hooking
6-2
(1)
Hook
Check
window
Temporary
latching brackets
Before temporarily
hooking
After temporarily
hooking
PIPING SIDE
engraved
mark
DRAIN SIDE
engraved mark
Make adjustments
Opening
Tool (e.g., screwdriver)
107~112mm
6-2
(6)
Panel
Lower side
of panel
Indoor unit
Lower part of hook of
the indoor unit
(The ceiling is
omitted from the
illustration for ease
of explanation)
107~112mm
Seal
Indoor unit
Lower part of
hook of the
indoor unit
Ceiling
Mounting bracket
Lower side of panel
Panel
Cross sections (4 points)
01_EN_3P257556-1.indd 5
01_EN_3P257556-1.indd 5
9/3/2009 4:05:02 PM
9/3/2009 4:05:02 PM