Optional Accessories of Operation Control System
C:3D043022D
Notes:
1.Installation box (No.4) is necessary for each adaptor marked
★
.
2.Electrical box (5-1/6-1) is required for controller (No. 5/6).
Building management system
Note:
★
1.BACnet
®
is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
★
2.L
ON
W
ORKS
is a registered trade mark of Echelon Corporation.
No.
Type
FXFQ~MVJU
FXSQ~MVJU
FXMQ~MVJU
FXAQ~MVJU
FXLQ~MVJU
FXNQ~MVJU
FXHQ~MVJU
FXDQ~MVJU
Item
1
Remote controller
Wireless
BRC7C812
BRC4C82
BRC7E818
—
BRC7E83
BRC4C82
Wired
BRC1C71
BRC1D71
2
Set back time clock
BRC15A71
3
Remote sensor
KRCS01-1
4
Installation box for adaptor PCB
KRP1B98
—
KRP1C93
KRP1B101
5
Central remote controller
DCS302C71
5-1
Electrical box
KJB311A
6
Unified on/off controller
DCS301C71
6-1
Electrical box
KJB212A
7
Schedule timer
DST301B61
8
External control adaptor for outdoor unit
★
DTA104A62
DTA104A61
—
DTA104A61
★
DTA104A62
★
DTA104A53
9
D3-NET Expander adaptor
DTA109A51
10
Simplified remote controller
—
BRC2A71
—
BRC2A71
—
BRC2A71
11
Adaptor for wiring
★
KRP1B72
KRP1B71
★
KRP1B73
—
12
Wiring adaptor for electrical appendices (2)
★
KRP4A73
KRP4A71
★
KRP4A72
★
KRP4A74
Part name
Model No.
Function
intellige
n
t To
uch
Control
ler
basic
Hardware
intelligent
Touch
Controller
DCS601C71
• Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Option
Software
Web
DCS004A71
• Monitors and controls the air conditioning system using the Internet and Web browser application
on a PC.
Co
mmunication
Lin
e
∗
2 Interface for use in BACnet
®
DMS502A71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
conditioning systems through BACnet
®
communications.
Optional DIII board
DAM411A1
Expansion kit, installed on DMS502A71, to provide 3 more DIII-NET communication ports. Not
usable independently.
Optional Di board
DAM412A1
Expansion kit, installed on DMS502A71, to provide 16 more wattmeter pulse input points. Not
usable independently.
∗
3 Interface for use in L
ON
W
ORKS
DMS504B71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
conditioning systems through L
ON
W
ORKS
communication.
Contact/Ana
log
sig
nal
Unification adaptor for computerized
control
DCS302A72
Interface between the central monitoring board and central control units
Wiring adaptor for electrical
appendices (2)
KRP4A71-74
To control the group of indoor units collectively, which are connected by the transmission wiring of
remote controller.
External control adaptor for outdoor
unit (Must be installed on indoor
units.)
DTA104A53, 61,
62
Cooling/Heating mode change over. Demand control and Low noise control are available between
the plural outdoor units.
Summary of Contents for BSVQ36MVJU
Page 1: ...SiUS30 604 Water Cooled Inverter Series Heat Pump Heat Recovery 60Hz ...
Page 7: ...SiUS30 604 vi Table of Contents Index i Drawings Flow Charts v ...
Page 13: ...Introduction SiUS30 604 xii ...
Page 27: ...Capacity Range SiUS30 604 14 General Information ...
Page 49: ...Specifications SiUS30 604 36 Specifications ...
Page 61: ...Refrigerant Flow for Each Operation Mode SiUS30 604 48 Refrigerant Circuit ...
Page 276: ...SiUS30 604 Piping Diagrams Appendix 263 1 3 BS Unit BSVQ36MVJU BSVQ60MVJU 4D045338 ...
Page 283: ...Wiring Diagrams SiUS30 604 270 Appendix FXLQ12M 18M 24MVJU FXNQ12M 18M 24MVJU 3D045644A ...
Page 284: ...SiUS30 604 Wiring Diagrams Appendix 271 2 4 BS Unit BSVQ36M 60MVJU 3D045069A ...
Page 305: ...Precautions for New Refrigerant R 410A SiUS30 604 292 Precautions for New Refrigerant R 410A ...
Page 309: ...SiUS39 601 iv Index ...