4 Operation

User reference guide

16

EJHA EHY32AA

Daikin Altherma hybrid monobloc

4P531181-1 – 2018.06

To configure which home pages are made available to the
end user

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [7.1.4]: 

  >  User  settings  >  Display  >  Available  home

pages.

Result: 

The  home  pages  that  are  possible  for  your  system

layout are listed.

2

Select a home page and press 

.

3

Do one of the following:

▪ To display the home page, select Yes and press 

.

▪ To hide the home page, select No and press 

.

4.6.7

Locking and unlocking buttons and
functions

About locking and unlocking

You can use the following locking modes:

▪ Button  lock:  Locks  all  buttons  to  prevent  children  from  changing

settings.

▪ Function  lock:  Locks  a  specific  function  to  prevent  people  from

changing its settings.

Possible function locks

Lock

If active, people cannot…

Room On/OFF

Turn ON or OFF the room
temperature control.

LWT On/OFF

Turn ON or OFF the main leaving
water temperature control.

Tank On/OFF

Turn ON or OFF the domestic
hot water control.

Temperature up/down

Adjust temperatures.

Quiet mode

Use quiet mode.

Holiday

Use holiday mode.

User settings

Change settings in [7]: 

 > User

settings.

DHW On/OFF

Turn ON or OFF the instant hot
water control.

To check if locking is active

1

Press 

 to go to one of the home pages.

2

If   is displayed, button lock is active.

Note: 

If  you  are  on  a  home  page  and  try  to  use  a  function  that  is

locked,   is displayed for 1 second.

To activate or deactivate button lock

1

Press 

 to go to one of the home pages.

2

Press 

 for more than 5 seconds.

To activate or deactivate a function lock

1

Press 

 to go to the menu structure.

2

Press 

 for more than 5 seconds.

3

Select a function and press 

.

4

Select Lock or Unlock, and press 

.

4.7

Preset values and schedules

4.7.1

Using preset values

About preset values

You  can  define  preset  values  for  multiple  controls.  Preset  values
make it easy to use the same value in many places (schedules and
room temperature home page (  and  )). If you later want to change
the value, you only have to do it in one place.

To define preset values

1

Go to [7.4]: 

 > User settings > Preset values.

2

Select  for  which  control  you  want  to  define  a  preset  value.

Example: 

Room temperature.

3

Select  a  preset  value  and  press 

Example: 

Comfort

(heating).

4

Select a temperature and press 

.

Possible preset values

Control

Preset value

Where used

Room
temperature

Comfort

▪ Room 

temperature

schedules

▪ Room  temperature  home

page  (   and  )  if  user
profile = Detailed

Eco

LWT main

Comfort

Main leaving water
temperature schedules

Eco

Tank
temperature

Storage comfort

DHW tank temperature
schedule if DHW tank mode
is

▪ Scheduled

▪ Sch reheat

Storage eco

Reheat

DHW tank temperature
schedule if DHW tank mode
= Sch reheat

Quiet level

Used when quiet mode is
set to On

Elec price

High

Medium

Low

Used when the savings
mode (installer setting) is set
to Economical.

Fuel price

Used when the savings
mode (installer setting) is set
to Economical.

4.7.2

Using and programming schedules

About schedules

Depending  on  your  system  layout  and  installer  configuration,
schedules (predefined and/or user‑defined) for multiple controls may
be available.

You can:

▪ Select which schedules you currently want to use.

▪ Program your own schedules if the predefined schedules are not

satisfactory. The actions you can program are control specific.

Possible actions per control

Control

Possible actions

Room temperature Program when to heat up a space:

▪ Comfort (preset value)

▪ Eco (preset value)

▪ [Custom temperature]

Main leaving water
temperature

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: