4 Operation
User reference guide
15
EJHA EHY32AA
Daikin Altherma hybrid monobloc
4P531181-1 – 2018.06
Usage example: You go away during the winter
If you are in the following situation:
▪ In 2 days, you go away for 2 weeks during the winter.
▪ You want to save energy, but prevent your house from freezing.
Then you can do the following:
Prerequisite:
You switched the permission level to Advanced end
user.
1
Configure the holiday. Go to [2]:
> Holiday, and configure
the following settings:
Setting
Value
Holiday mode
Away
From
2 February 2014
Until
16 February 2014
Operation mode
Heating
Heating
12°C
2
Activate the holiday mode.
▪ Go to [2.1]:
> Holiday > Holiday.
▪ Select Yes and press
.
Advantage:
▪ Before and after your holiday, your normal schedule will be used.
▪ During your holiday, you save energy and prevent your house
from freezing.
Usage example: You come home during your holiday
If you are in the following situation:
▪ You configured and activated the holiday mode (Away).
▪ During your holiday, you come home for a few hours and want to
use your normal schedule.
Then you can do the following:
1
Deactivate the holiday mode.
2
When you go away again, activate the holiday mode again.
Advantage:
You do NOT have to change your schedule or holiday configuration.
4.6.4
Reading out information
To read out information
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [6]:
> Information.
Possible read-out information
In menu…
You can read out…
[6.1] Sensor information
Room, tank or DHW, outside,
and leaving water temperature.
(If applicable)
[6.2] Energy metering
Consumed electricity, and
consumed gas.
[6.3] Error handling
Error history and contact/
helpdesk number.
[6.4] User permission level
Current user permission level.
[6.5] Actuators
Status/mode of each actuator.
Example:
Domestic hot water
pump ON/OFF.
[6.6] Operation modes
Current operation mode.
Example:
Defrost/oil return
mode.
[6.7] Running hours
Running hours of the system.
In menu…
You can read out…
[6.8] Version
Version information about the
system.
4.6.5
Configuring date, time, units of
measurement, contrast and backlight
To configure time and date
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [1]:
> Set time/date.
INFORMATION
Switch to Adv. end user to change daylight saving time and
12/24h notation.
To configure units of measurement
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [7.6]:
> User settings > Unit of measurement.
Possible units of measurement settings
Setting
Possible units of measurement
Decimal point
▪ Dot
▪ Comma
Temperature
▪ °C
▪ °F
Consumed gas
▪ m³
▪ ft³
▪ kWh
For correct operation, only use
kWh. Do NOT use m³ or ft³.
To configure the contrast of the user interface
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [7.1.1]:
> User settings > Display > Contrast.
To configure the backlit LCD time of the user interface
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [7.1.2]:
> User settings > Display > Backlit LCD time.
4.6.6
Configuring user profile and home pages
To set a user profile
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [7.1.3]:
> User settings > Display > User profile.
2
Select a user profile and press
.
Possible user profiles
If user profile = Detailed, you can see and do more on the home
pages.
User profile = Basic
User profile = Detailed
15:20
20.0°C
Mon
Room
Actual temperature
15:20
20.0°C
17:30
Actual temperature
Room
Scheduled
Mon
Tue