6 Energy visualisation

User reference guide

21

EJHA EHY32AA
Daikin Altherma hybrid monobloc
4P531181-1 – 2018.06

3

Press 

 to save the schedule.

INFORMATION

The values for High, Medium and Low correspond with the
electricity  price  values  for  High,  Medium  and  Low
previously set. If no schedule is set, the electricity price for
High is taken into account.

5.4

About energy prices in case of an
incentive per kWh renewable
energy

An  incentive  can  be  taken  into  account  when  setting  the  energy
prices.  Although  the  running  cost  can  increase,  the  total  operation
cost, taking into account the reimbursement will be optimized.

NOTICE

Make sure to modify the setting of the energy prices at the
end of the incentive period.

5.4.1

To set the fuel price in case of an
incentive per kWh renewable energy

Prerequisite: 

Calculate the value for the fuel price with the following

formula: actual fuel price+(incentive/kWh×0.9)

1

Go to [7.4.6]: 

 > User settings > Preset values > Fuel price.

2

Use 

 and 

 to set the correct price.

3

Press 

 to confirm.

5.4.2

To set the electricity price in case of an
incentive per kWh renewable energy

Prerequisite: 

Calculate  the  value  for  the  electricity  price  with

following formula: actual electricity price+incentive/kWh.

1

Go to [7.4.5]: 

 > User settings > Preset values > Elec price.

2

Use 

 and 

 to set the correct prices for High, Medium and

Low, according to your electricity tariff.

3

Press 

 to confirm.

INFORMATION

Solar  panels.

  If  solar  panels  are  used,  set  the  electricity

price value very low to promote the use of the heat pump.

5.4.3

Example

This  is  an  example  and  the  prices  and/or  values  used  in  this
example are NOT accurate.

Data

Pence/kWh

Gas price

4.08

Electricity price

12.49

Renewable heat incentive per
kWh

5

Calculation of the gas price:

Gas price=Actual gas price+(incentive/kWh×0.9)

Gas price=4.08+(5×0.9)

Gas price=8.58

Calculation of the electricity price:

Electricity price=Actual electricity price+incentive/kWh

Electricity price=12.49+5

Electricity price=17.49

Price

Value in breadcrumb

Gas: 4.08 pence/kWh

[7.4.6]=8.58

Electricity: 12.49 pence/kWh

[7.4.5]=17.49

6

Energy visualisation

The user interface is able to graphically display energy statistics for:

▪ consumed electricity: calculated by the interface itself based on an

internal calculation.

▪ consumed gas (only in case of EHY32AA gas boiler):

calculated by the interface itself based on an internal calculation.

6.1

To view the energy statistics

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [6.2]: 

 > Information > Energy metering.

2

Select Consumed elec. or Consumed gas.

3

Use  the 

  and 

  buttons  to  toggle  between  views  of  the

current  month,  the  previous  month,  the  last  12  months  and  a
general overview.

4

Use  the 

  and 

  buttons  to  toggle  between  different  modes

(if applicable).

7

Energy saving tips

Tips about room temperature

▪ Make sure the desired room temperature is NEVER too high, but

ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If

necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature. 

Example: 

When  you  have  a  party,  or  when  you

are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode. 

Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

Tips about leaving water temperature

▪ In  heating  mode,  a  lower  desired  leaving  water  temperature

results in lower energy consumption and better performance.

▪ Set the desired leaving water temperature in accordance with the

heat  emitter  type. 

Example: 

Underfloor  heating  is  designed  for

lower  leaving  water  temperature  than  radiators  and  heat  pump
convectors.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage

comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: