background image

3 About the system

User reference guide

4

EJHA EHY32AA

Daikin Altherma hybrid monobloc

4P531181-1 – 2018.06

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format: Paper (in the box of the outdoor unit) + Digital files on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Available screens

Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.

Breadcrumbs

1

20.0°C >
18.0°C >

7.4.1.1

Room temperature

Comfort (heating)
Eco (heating)

Select

Scroll

Breadcrumbs help you to locate where you are in the menu structure
of  the  user  interface.  This  document  also  mentions  these
breadcrumbs.

Example: 

Go  to  [7.4.1.1]: 

  >  User  settings  >  Preset  values  >

Room temperature > Comfort (heating)

3

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Produce domestic hot water

NOTICE

Filling the water circuit

. Must be done by the installer to

make sure that the system can cold start up.

NOTICE

During holidays

. Do NOT turn OFF the power supply. The

power  is  needed  for  the  frost  protection  functions  of  the
outdoor unit. Use the holiday mode instead.

3.1

About freeze protection

Frost can damage the system. To prevent the hydraulic components
from  freezing,  the  heat  pump's  software  is  equipped  with  special
frost  protection  functions.  These  functions  activate  the  pump,  the
heat  pump  and  the  gas  boiler  when  the  temperature  becomes  too
low.

However,  in  case  of  a  power  failure,  these  functions  cannot
guarantee  protection.  Therefore  the  installer  provided  extra
protection by doing one of the following:

▪ The  installer  added  glycol  to  the  water  circuit.  Glycol  lowers  the

freezing point of the water.

▪ The  installer  installed  freeze  protection  valves.  Freeze  protection

valves drain the water from the system before it can freeze.

3.2

Components in a typical system
layout

Gas boiler (EHY32AA) + instant domestic hot water
(not for Switzerland)

a

b

c

e

f

d

B

C

A

Gas boiler (EHY32AA) + domestic hot water tank

a

b

c

e

f

d

B

C

A

Gas boiler (third party) + instant domestic hot water (not for
Switzerland)

a

b

c

e

f

d

B

C

A

A

Living room.

B

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Gas boiler

c

Instant domestic hot water or domestic hot water (DHW) tank

d

Heat pump convectors or fan coil units

e

User interface in the living room, used as room thermostat

f

Radiators

4

Operation

4.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: