8 Maintenance and service

User reference guide

22

EJHA EHY32AA

Daikin Altherma hybrid monobloc

4P531181-1 – 2018.06

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

8

Maintenance and service

8.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure indicated on the gas boiler is

above 1 bar. Switch off the boiler to see the pressure on the main
display of the gas boiler. Ignore the error that appears on the user
interface.  When  you  turn  the  gas  boiler  back  on,  the  error  will
disappear.

▪ Make  sure  that  electricity  and  gas  prices  defined  in  the  user

interface are up-to-date.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant charge in the system (expressed as tonnes CO

2

equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

8.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  >  Information  >  Error  handling  >  Contact/

helpdesk number.

9

Troubleshooting

9.1

Overview: Troubleshooting

If a malfunction occurs,   is displayed on the home pages. You can
press 

 to display more information about the malfunction.

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

9.2

To check the error history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go to [6.3.1]: 

 > Information > Error handling > Error history.

9.3

To check the warning history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go  to  [6.3.1]: 

  >  Information  >  Error  handling  >  Warning

history.

9.4

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: