4 Operation

User reference guide

17

EJHA EHY32AA
Daikin Altherma hybrid monobloc
4P531181-1 – 2018.06

Control

Possible actions

DHW tank
temperature

Program when to heat up the DHW tank:

▪ Storage comfort (preset value)

(a)

▪ Storage eco (preset value)

(a)

▪ Storage stop

(b)

Quiet mode

Program when the unit has to use which quiet
mode level:

▪ Level 1

▪ Level 2

▪ Level 3

▪ OFF

(Only for field
supplied
domestic hot
water pump for
secondary return)

Domestic hot water
pump

Program when the domestic hot water pump is
turned ON and OFF.

Electricity price

Program when a certain electricity tariff is valid.

(a)

Start heating up until the desired setpoint (Comfort/Eco) is
reached.

(b)

Stop heating, even if the desired temperature is not
reached yet; example: if electric tariffs are higher during the
day, you can program a stop at 06:00.

To select which schedule you currently want to use

1

Go to [5]: 

 > Select schedules.

2

Select for which control you want to use a schedule. 

Example:

[5.1] Room temperature.

3

Select  for  which  operation  mode  you  want  to  use  a  schedule.

Example: 

[5.1.1] Heating .

4

Select a predefined or user‑defined schedule and press 

.

To program a schedule

1

Go to [7.3]: 

 > User settings > Set schedules.

2

Open an empty, predefined or user‑defined schedule.

3

Change it.

4

Save it.

Guidelines when programming

07

:00

-- : --     --

Set heating schedule

Mon

Comfort

Select

Scroll

Delete line
Clear day schedule
Copy day
Save schedule

You can:

▪ Delete lines from the schedule

▪ Clear a day schedule

▪ Copy from one day to others

Usage example: You work in a 3-shift system

If you work in a 3-shift system, you can do the following:

1

Program  3  room  temperature  schedules  in  heating  mode  and
give  them  appropriate  names. 

Example: 

EarlyShift,  DayShift

and LateShift

2

Select the schedule that you currently want to use.

4.7.3

Schedules: Example

INFORMATION

The procedures to program other schedules are similar.

In this example:

▪ Room temperature schedule in heating mode

▪ Monday = Tuesday = Wednesday = Thursday = Friday

▪ Saturday = Sunday

To program the schedule

1

Go  to  [7.3.1.1]: 

  >  User  settings  >  Set  schedules  >  Room

temp. > Set heating schedule.

2

Select Empty and press 

.

3

Program the schedule for Monday. See below for more details.

4

Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.

5

Program the schedule for Saturday.

6

Copy from Saturday to Sunday.

7

Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.

To program the schedule for Monday

1

Use 

 and 

 to select Monday.

2

Press 

 to enter the schedule for Monday.

3

Program the schedule for Monday:

▪ Use 

 and 

 to select an entry.

▪ Use 

 and 

 to change the value of an entry.

To copy from one day to another

1

Select  the  day  from  which  you  want  to  copy  and  press 

.

Example: 

Monday.

2

Select Copy day and press 

.

3

Set the days you want to copy to Yes and press 

Example:

Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.

To save the schedule

1

Press 

, select Save schedule and press 

.

2

Select  User  defined  1,  User  defined  2  or  User  defined  3  and
press 

.

3

Change  the  name  and  press 

.  (Only  applicable  for  room

temperature schedules). 

Example: 

MyWeekSchedule

4.7.4

Predefined schedules: Room temperature
+ leaving water temperature (main)

: Desired temperature = Preset value (Comfort)

: Desired temperature = Preset value (Eco)

Predefined 1

Mon - Fri

07:00 09:00

17:00

23:00

Sat - Sun

23:00

08:00

Predefined 2

Mon - Fri

07:00 09:00

17:00

12:00

23:00

14:00

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: