4 Operation

User reference guide

5

EJHA EHY32AA
Daikin Altherma hybrid monobloc
4P531181-1 – 2018.06

Part

Description

Basic usage

Information about:

▪ Home  pages,  where  you  can  read  out

and  change  settings  that  are  meant  for
daily usage

▪ Menu structure, where you can read out

and  configure  settings  that  are  NOT
meant for daily usage

▪ ON/OFF controls

Space heating control

How to control space heating:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

▪ How  to  control  domestic  hot  water  in

case of instant DHW

▪ How  to  control  domestic  hot  water  in

case of tank:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Advanced usage

Information about:

▪ Changing the user permission level

▪ Quiet mode

▪ Holiday mode

▪ Reading out information

▪ Date,  time,  units  of  measurement,

contrast and backlight

▪ User profile and home pages

▪ Locking  and  unlocking  buttons  and

functions

Preset values and
schedules

▪ How to use preset values

▪ How to select and program schedules

▪ Overview of predefined schedules

Weather-dependent
operation

How to set the weather-dependent settings

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

4.2

The user interface at a glance

4.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches between home pages (when you are on a home

page).

▪ Goes to the default home page (when you are in the menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages.
Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens  the  menu  structure  (when  you  are  on  a  home

page).

▪ Goes  up  a  level  (when  you  are  navigating  through  the

menu structure).

▪ Goes back 1 step (example: when you are programming a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or

between  displaying  actual  and  offset  values  (if  applicable)
on the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

▪ Enables you to activate or deactivate button lock if pressed

for more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed for more than 5 seconds in the main menu of the
menu structure.

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

4.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Not available.

Heat pump (compressor) operation or boiler
operation. This symbol is related to the home page.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

Summary of Contents for Altherma EHY2KOMB28AA

Page 1: ...User reference guide Daikin Altherma hybrid monobloc English User reference guide Daikin Altherma hybrid monobloc EJHA04AAV3 EHY2KOMB28AA EHY2KOMB32AA...

Page 2: ...schedules Room temperature leaving water temperature main 17 4 7 5 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 M...

Page 3: ...arts must be done by an authorized installer and must comply with applicable legislation Units must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this pro...

Page 4: ...an cold start up NOTICE During holidays Do NOT turn OFF the power supply The power is needed for the frost protection functions of the outdoor unit Use the holiday mode instead 3 1 About freeze protec...

Page 5: ...F one of the controls room temperature leaving water temperature DHW tank temperature d MENU STRUCTURE BACK Opens the menu structure when you are on a home page Goes up a level when you are navigating...

Page 6: ...Tank Instant DHW DHW To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu structure About the menu structure Y...

Page 7: ...are Yes NOT linked You can set the leaving water set point on the home page Is displayed next to the set point Then leaving water set point and room temperature set point are No Linked by their preset...

Page 8: ...y using or to adjust the temperature Result The room temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or...

Page 9: ...ct Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save ene...

Page 10: ...erature is permanent unless the leaving water temperature is according to a schedule In that case the overruling is valid until the next scheduled action 1 Go to 7 4 2 User settings Preset values LWT...

Page 11: ...e home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode Reheat mode In reheat mode the DHW tank continuously heats up...

Page 12: ...times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt DHW tank temperature t Time 60 C Storage comfort 50 C Storage eco 45 C Reheat 35 C Reheat tank temperature hysteresis v...

Page 13: ...can read out in the menu structure depends on your user permission level End user default Adv end user You can read out more information To set the user permission level to Advanced end user 1 Go to...

Page 14: ...tings will be used To check if holiday mode is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activate...

Page 15: ...handling Error history and contact helpdesk number 6 4 User permission level Current user permission level 6 5 Actuators Status mode of each actuator Example Domestic hot water pump ON OFF 6 6 Operat...

Page 16: ...re than 5 seconds 3 Select a function and press 4 Select Lock or Unlock and press 4 7 Preset values and schedules 4 7 1 Using preset values About preset values You can define preset values for multipl...

Page 17: ...do the following 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the schedule that you currently want to use 4...

Page 18: ...mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prerequisite You switched the permission level to Ad...

Page 19: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of mea...

Page 20: ...in Contact helpdesk number 5 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for...

Page 21: ...ics for consumed electricity calculated by the interface itself based on an internal calculation consumed gas only in case of EHY2KOMB28 32AA gas boiler calculated by the interface itself based on an...

Page 22: ...an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than...

Page 23: ...mp failure occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the boiler can take over the e...

Page 24: ...or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application e...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P531181 1 2018 06 Copyright 2018 Daikin...

Reviews: