You already consumed most of your hot water.
▪
You cannot wait for the next scheduled action to heat up the DHW tank.
Then you can activate DHW powerful operation.
Advantage:
The DHW tank immediately starts heating up the water to the preset
value (Storage comfort).
INFORMATION
When powerful operation is active, the risk of space heating/cooling and capacity
shortage comfort problems is significant. In case of frequent domestic hot water
operation, frequent and long space heating/cooling interruptions will happen.
Comfort setpoint
Only applicable when domestic hot water preparation is
Schedule only
or
Schedule + reheat
. When programming the schedule, you can make use of
the comfort setpoint as a preset value. When you later want to change the storage
setpoint, you only have to do it in one place.
The tank will heat up until the
storage comfort temperature
has been reached. It
is the higher desired temperature when a storage comfort action is scheduled.
Additionally, a storage stop can be programmed. This feature puts a stop to tank
heating even if the setpoint has NOT been reached. Only program a storage stop
when tank heating is absolutely undesirable.
#
Code
Description
[5.2]
[6-0A]
Comfort setpoint
:
▪
30°C~[6‑0E]°C
Eco setpoint
The
storage economic temperature
denotes the lower desired tank temperature.
It is the desired temperature when a storage economic action is scheduled
(preferably during day).
#
Code
Description
[5.3]
[6-0B]
Eco setpoint
:
▪
30°C~min(50,[6‑0E])°C
Reheat setpoint
Desired reheat tank temperature
, used:
▪
in
Schedule + reheat
mode, during reheat mode: the guaranteed minimum
tank temperature is set by the
Reheat setpoint
minus the reheat hysteresis.
If the tank temperature drops below this value, the tank is heated up.
▪
during storage comfort, to prioritize the domestic hot water preparation. When
the tank temperature rises above this value, domestic hot water preparation and
space heating/cooling are executed sequentially.
#
Code
Description
[5.4]
[6-0C]
Reheat setpoint
:
▪
30°C~min(50,[6‑0E])°C
Schedule
You can set the tank temperature schedule using the schedule screen. For more
information about this screen, see
"8.3.8 Schedule screen: Example"
110].