14
|
Technical data
Installer reference guide
208
EPGA11~ EAV23DA6V
Daikin Altherma 3 H F
4P606487-1 – 2019.12
NOTES:
1
Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN: green, YLW:
yellow, PNK: pink, ORG: orange.
2
This wiring diagram applies only to the outdoor unit.
3
When operating, do not short-circuit protective devices S1PH and S1PL
4
Refer to the combination table and the option manual for how to connect
the wiring to X6A, X4A and X41A.
5
Refer to the service manual for instructions on how to set the selector
switches (DS1). The factory setting of all switches is OFF.
(3) Legend
English
Translation
Legend
Legend
Field supply
Field supply
Optional
Optional
Part n°
Part n°
Description
Description
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
A3P
Printed circuit board (leakage current)
A4P
Printed circuit board (ACS)
BS1~BS4 (A1P)
Push button switch
C1~C4 (A1P, A2P)
Capacitor
DS1 (A1P)
Dipswitch
E1H
Crankcase heater
E2H
Bottom plate heater (option)
E3H~E5H
Plate heat exchanger heaters
F1U~F4U (A2P)
Fuse
F6U (A1P)
Fuse (T 5.0 A / 250 V)
H1P~H7P (A1P)
Light-emitting diode (service monitor is orange)
HAP (A1P)
Light-emitting diode (service monitor is green)
K1R (A1P)
Magnetic relay (Y1S)
K1R (A4P)
Magnetic relay (E3H~E5H)
K2R (A1P)
Magnetic relay (Y2S)
K2R (A4P)
Magnetic relay (E2H)
K3R (A1P)
Magnetic relay (Y3S)
K4R (A1P)
Magnetic relay (E1H)
K10R (A1P)
Magnetic relay
K11M (A1P)
Magnetic contactor