2
Fix the cable with cable ties to the cable tie mountings.
7.6.14 To connect the space cooling/heating ON/OFF output
INFORMATION
Cooling is only applicable in case of:
▪
Reversible models
▪
Heating only conversion kit (EKHVCONV2)
1
Connect the space cooling/heating ON/OFF output cable to the appropriate
terminals as shown in the illustration below.
X1M
X2M
A4P
X5M
X1M
YC
Y1
Y2
Y3
Y4
YC
Y2
a
7 9
b
a
Installation of EKRP1HBAA is required.
b
Prewiring between X2M/7+9 and Q1L (= thermal protector backup heater). Do NOT change.
2
Fix the cable with cable ties to the cable tie mountings.
7.6.15 To connect the changeover to external heat source
1
Connect the changeover to external heat source cable to the appropriate
terminals as shown in the illustration below.
X1M
X2M
A4P
X5M
X1M
YC
Y1
Y2
Y3
Y4
X2 X1
X2M
X4 X3
N L
a
a
Installation of EKRP1HBAA is required.
2
Fix the cable with cable ties to the cable tie mountings.