8
|
Configuration
Installer reference guide
107
EPGA11~ EAV23DA6V
Daikin Altherma 3 H F
4P606487-1 – 2019.12
Submenu
Description
[3]
Additional zone
Restriction:
Only displayed if there are two
leaving water temperature zones. Shows the
applicable symbol for your additional zone
emitter type.
Set the leaving water temperature for the
additional zone (if present).
[4]
Space heating/
cooling
Shows the applicable symbol for your unit.
Put the unit in heating mode or cooling mode.
You cannot change the mode on heating only
models.
[5]
Tank
Restriction:
Only displayed if a domestic hot
water tank is present.
Set the domestic hot water tank temperature.
[7]
User settings
Gives access to user settings such as holiday
mode and quiet mode.
[8]
Information
Displays data and information about the
indoor unit.
[9]
Installer settings
Restriction:
Only for the installer.
Gives access to advanced settings.
[A]
Commissioning
Restriction:
Only for the installer.
Perform tests and maintenance.
[B]
User profile
Change the active user profile.
[C]
Operation
Turn heating/cooling functionality and
domestic hot water preparation on or off.
8.3.4 Menu screen
Example:
7.1
Language
Time/date
Holiday
Possible actions on this screen
Go through the list.
Enter the submenu/setting.
8.3.5 Setpoint screen
The setpoint screen is displayed for screens describing system components that
need a setpoint value.