6-41
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6.7.2.29 F49: Current increase and decrease by single-clicking
To increase/decrease the welding current by the torch switch operation, set the current increase/
decrease volume at single-clicking. This function is available when the internal function F48 (Adjusting
current with torch switch) is set to [ON].
•
Set the current increase/decrease volume by single-clicking in the range of -50 to 50 A.
6.7.2.30 F50: Current increase and decrease by double-clicking
To increase/decrease the welding current by the torch switch operation, set the current increase/
decrease volume at double-clicking. This function is available when the internal function F48 (Adjusting
current with torch switch) is set to [ON].
•
Set the current increase/decrease volume by double-clicking in the range of -50 to 50 A.
6.7.2.31 F51: Special crater repeat
In the sequence of main welding of the "CRATER-FILL ON (REPEATED)" (during start input holding),
the torch switch operation can switch the welding and crater treatment repeatedly as many time as
needed.
•
[ON]: Setting of "CRATER-FILL ON (REPEATED)" is applied, and transits to the crater treatment by
single-clicking of the torch switch during the welding sequence (start input holding). It is available to
return to the main welding as many times as needed even after transit to the crater treatment by single-
clicking of the torch switch.
When this function is enabled, the LED of "CRATER-FILL ON (REPEATED)" of the CRATER-FILL key
flashes.
•
[OFF]: disables the function.
T I P S
• When this function is set to [ON], automatically the setting of "CRATER-FILL ON
(REPEATED)" is selected, disabling other welding modes. (The CRATER-FILL key does not
work.)
• Single-clicking operation should be within 0.3 seconds.
• At the time of transition to crater, press the torch switch for at least 0.3 seconds.
• Welding method at crater treatment is the same as that of main welding.