6-13
Chapter 6
W
elding Condition
M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
1.
Turn off the power switch.
2.
With the LOAD key and the SAVE key depressed together, turn ON the power switch.
3.
Turn the parameter adjustment knob, and select the JOB No. to delete.
4.
Press the ENTER key.
5.
Press the ENTER key.
6.
Check that "End" is displayed on the left/right digital meters and turn off the power switch.
⇒
The power LED switch lights off. The status returns to normal when the power switch is turned on.
●
Depress these two keys until "dEL" is displayed on
the left digital meter. Release the keys after "dEL" is
displayed.
⇒
"dEL" is displayed when the system transits to the
DELETE mode.
⇒
The JOB No. (registration No.) is displayed on the
right digital meter in a flashing mode, and the LED
of JOB No. lights up.
●
To delete all the registration at the same time, turn
the parameter adjustment knob counterclockwise, to
display "ALL" on the right digital meter.
When "ALL" is selected, the current welding
condition set on the operation panel is also deleted,
and the welding parameters including the internal
functions return to the initial values.
⇒
The display "dEL" on the left digital meter starts
flashing.
⇒
Pressing the DISPLAY CHANGE key enables to
check the value of welding parameter of the JOB No.
to delete. The set values are displayed on the left/
right digital meters in a flashing mode.
⇒
To change the JOB No. to delete, press the LOAD key
or the SAVE key. The display returns to the status
described in step 2.
⇒
To cancel the deletion, turn off the power switch. The
delete mode is terminated.
⇒
The welding condition of the selected JOB No. is
deleted, and "End" is displayed on the left/right
digital meters.
A
V
r
㧑
ON
+
WARNING
IPM.
sec.
JOB No.
LOAD
SAVE
Hz
A
V
r
㧑
ARNING
IPM.
sec.
JOB No.
Hz
A
V
㧑
WARNING
IPM.
sec.
JOB No.
r
ENTER
㧔
3 sec.
㧕
Hz
A
V
r
㧑
WARNING
IPM.
sec.
JOB No.
Hz