6-35
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
14
ON (close)
OFF (open)
ON (close)
ON (close)
15
OFF (open)
ON (close)
ON (close)
ON (close)
16
ON (close)
ON (close)
ON (close)
ON (close)
The external input terminal without the setting "5" is regarded as signal OFF. Accordingly, for the function (external input
terminal) which does not require the "ON" status for the JOB No. to read can be set to other functions.
Example 1) In reading out the welding condition of the JOB No.3;
Setting F30 to "5" and turning the signal of external input terminal IN-EXT2 to ON enable to read out the JOB No. 3.
For F29, F31, and F32, other functions can be set.
Example 2) In reading out the welding condition of the JOB No.3;
Setting F29 to F32 to "5" and turning the signal of external input terminal IN-EXT2 to OFF enable to read out the JOB No.
3.
Example 3) In reading out the welding condition of the JOB No.7;
Setting F30 and F31 to "5" and turning the two signals of the external input terminal IN-EXT2/IN-EXT3 to ON enable to
read out the JOB No. 7. For F29 and F32, other functions can be set.
*5: The JOB No. shifts to the following number and read out the condition by causing short circuit between terminals
for 300msec during JOB shift mode.
If the JOB No. shifts to the largest number, it shifts to the smallest number.
*6: The JOB No. shifts to the previous number and read out the condition by causing short circuit between terminals
for 300msec during JOB shift mode.
If the JOB No. shifts to the smallest number, it shifts to the largest number.
*7: When welding condition is not registered in the JOB No., it shifts to the registered JOB No.
The condition can not be changed during welding.
To release the JOB shift mode, release the external input terminals. The digital meter displays current and voltage
after 2 sec have passed.