F11: Fine adjustment of welding conditions memory
When the analog remote control (optionally available) is used, fine adjustment of the welding current
and welding voltage of welding condition stored on the welding condition memory is available. This
function is effective when the internal function F4 (Auto/Semi-auto mode) is set to "0".
•
[OFF]: disables the function.
•
[1] to [30]: enables the function. Turning the welding current adjustment knob on the analog remote
control enables to fine adjust the current, and turning the voltage knob enables to fine adjust the voltage.
–
Setting range : 1 to 30 %
–
Turning both of the current and voltage knobs to the center of scales sets the welding conditions to
those stored on the welding condition memory. Adjust the current/voltage with the standard of the
center of scales. To increase the welding current or voltage, turn the knob counterclockwise and to
reduce the welding current or voltage, turn the knob clockwise.
•
In the following cases, this function cannot be used:
–
Welding conditions are not registered to the memory;
–
Analog remote control (optional) is not connected to the welding power source;
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
–
Internal function F4 (Auto/Semi-auto mode) is set to a value other than "0" (Semi-auto mode).
6.7.2.10 F13: Turbo start
The welding power source has the turbo start function using capacitor discharge in order to obtain
smooth welding start.
•
[ON]: enables the function.
•
[OFF]: disables the function.
T I P S
• If wire burning is too strong at the welding start, set this function to [OFF] to disable the turbo
start function (disables the function).
SINERG. FINE ADJ.
LOW
HIGH
INCHING
JOB No.
Welding current(A)
For CO2/MAG/MIG
Place these knobs in the center positions.