S
PECIFICATION
P
RODUCT
S
PECIFICATION
AND
C
ONFIGURATION
C
HAPTER
2
2-2
2.1.2
Applicable welding method
This section explains the applicable welding method (shield gas/wire type/welding type) and wire
diameter.
Standard specification
WELDING
METHOD
GAS (*1)
WIRE MATERIALS
WIRE DIA. [in. (mm)]
TRAVEL SPEED
Penetration
adjustment
DC
CO
2
MILD STEEL
030 / .035 / .040 /.045
(0.8/0.9/1.0/ 1.2)
(*2) (*3)
Enable
MAG (20 % CO
2
)
(*1-1)
MILD STEEL
.030 / .035 / .040 /.045
(0.8/0.9/1.0/1.2)
(*2) (*3)
Enable
MILD STEEL CORED
.045 / .052 (1.2/1.4)
STANDARD (*3)
Enable
STAINLESS CORED
.045 (1.2)
STANDARD (*3)
Enable
MIG (2 % O
2
)
(*1-2)
STAINLESS STEEL
.030 / .035 / .040 /.045
(0.8/0.9/1.0/1.2)
(*2) (*3)
Enable
MIG (100 % Ar)
(*1-3)
SOFT ALUMINUM
.045 / 1/16 (1.2/1.6)
(*2) (*3)
-
HARD ALUMINUM
.045 / 1/16 (1.2/1.6)
(*2) (*3)
-
*1: Note that the "collective" voltage adjustment may not meet the appropriate condition if a mixing gas other than those
with the following mixing ratios is used.
*1-1: MAG gas: Argon (Ar) 80 % + Carbon dioxide (CO
2
)20 %
*1-2: MIG gas (stainless steel): Argon(Ar) 98 % + Oxygen (O
2
)2 %
*1-3: MIG gas (Aluminum/Aluminum bronze/Silicon bronze): Argon (Ar)100 %
*2: Available for applications either of "STANDARD" or "HIGH".
*3: For "STANDARD" mode, the standard mode or extended cable mode (extended mode of power cable) is available.
(