L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-4
F46
Special crater sequence
initial time
0.0 to 10.0
0.0 (s)
Sets initial time in the special crater sequence.
(available when "ON" is selected in F45)
○
F47
Special crater sequence
crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the special crater sequence.
(available when F45 is enabled)
○
F48
Adjusting current with torch
switch
OFF/ON
OFF
With the setting of "Crater" and in the welding
condition (during start input holding), sets
whether to adjust current by the torch switch
operation:
OFF: not to use torch switch
ON: uses torch switch (increase/decrease
volume set by F49 and F50 are applied).
○
F49
Current increase and
decrease by single-clicking
-50 to 50
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON"
is selected in F48)
○
F50
Current increase and
decrease by double-clicking
-50 to 50
0 (A)
Sets current increase/decrease volume by double
clicking of the torch switch. (available when "ON"
is selected in F48)
○
F51
Special crater repeat
OFF/ON
OFF
With the setting of "Crater," sets whether to switch
the welding condition and crater condition by the
click operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
○
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command /
Feeding command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current /
Sequence information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage /
Sequence information
7: Welding current / Feeding command /
Sequence information
8: Welding voltage / Feeding command /
Sequence information
-
F53
Sampling speed of data log
function
1/2/3
1
Sets sampling interval of the data log function:
1: 10 ms
2: 100 ms
3: 1 s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown
speed at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with OTC automatic
machine.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
No.
Function Name
Setting range
Initial value
Explanation
Memory