Quick Start Guide
38
Step 2
View the authorization progress.
●
Sync SubControl Person: Sync personnel on the main controller to the sub-controller.
●
Sync Local Person: Sync personnel on the management platform of the main controller
to its server.
●
Sync Local Time: Sync the time templates in the area permissions to the sub-controller.
Figure 5-20 Authorization progress
Step 3
(Optional) If authorization failed, click to try again.
You can click
to view details on the failed authorization task.
5.2.10 Configuring Global Alarm linkages (Optional)
You can configure global alarm linkages across different Access Controllers.
Background Information
When you have configured both global alarm linkages and local alarm linkages, and if the global
alarm linkages conflict with the local alarm linkages, the last alarm linkages you have configured will
take effective.
Procedure
Step 1
Select
Access Control Config
>
Global Alarm Linkage
.
Step 2
Configure the alarm output.
1. Select an alarm input from the alarm input channel list, and then click
Link Alarm
Output
.
2. Click
Add
, select an alarm output channel, and then click
OK
.
Figure 5-21 Alarm output
3. Turn on the alarm output function and then enter the alarm duration.