Figure 5-5 Configure door parameters
Table 5-1 Parameter description
Parameter
Description
Entry Card Reader
Select the card reader protocol.
●
Wiegand: Connects to a wiegand reader. You can connect the
LED wire to the LED port of the controller, and the reader will
beep and flash when the door unlocks.
●
OSDP: Connects to an OSDP reader.
●
RS-485: Connects to an OSDP reader.
Exit Button
Connects to a exit button.
Door Detector
Connects to a door detector.
Power Supply of Locks
●
12 V: The controller provides power for the lock.
◇
Fail secure: When the power is interrupted or fails, the door
stays locked.
◇
Fail safe: When the power be interrupted or fails, the door
automatically unlocks to let people leave.
●
Relay: The relay supplies power for the lock.
◇
Relay open = locked: Sets the lock to remain locked when
the relay is open.
◇
Relay open = unlocked: Sets the lock to unlock when the
relay is open.
Step 5
Configure access control parameters.
Step 6
In
Unlock Settings
, select
Or
or
And
from
Combination Method
.
●
Or: Use one of the selected unlock methods to authorize opening the door.