Quick Start Guide
10
3 Wring of Locks
This section use lock wiring of two-door solution as an example. The wiring of lock might differ
depending on the lock type that you configured.
●
configure lock for
Relay
.
◇
Relay Open = Unlocked: Set the lock to unlock when the relay is open.
◇
Relay Open = Locked: Set the lock to remain locked when the relay is open.
●
Configure lock for
12V
.
◇
Fail Secure: Sets the lock to remain locked during power outages.
◇
Fail Safe: Sets the lock to unlock during power outages.
3.1 Wiring of Magnetic Locks
3.1.1 Wring of Dual Magnetic Locks with PoE (12V and Relay)
Supplies power for the Access Controller over the same Ethernet cable. One door uses the external
power supply, and the other uses the Access Controller to supply power.
1. Select
Relay Open = Unlocked
from the
Relay
list for lock 1 (door 1).
Figure 3-1 Lock 1 (door 1)
2. Select
Fail Safe
from the
12V
list for lock 2 (door 2).
Figure 3-2 Lock 2 (door 2)
3. Wiring the locks according to the diagram below.