Quick Start Guide
8
Figure 2-8 Lock ports
Table 2-8 Description of lock
Ports
Description
L1/L2
Power one or two locks (DC output). The lock connector can also be used
to power external devices.
Connects to lock. 12 VDC Max total load = 1000 mA
●
For controlling up to 12 V lock.
●
Connect locks and loads to the pins according to the wiring diagram
generated through the hardware configuration. For details, see "3
Wring of Locks".
REL2
–
Grounding wire.
Figure 2-9 RS-485 ports
Table 2-9 Description of RS-485
Ports
Description
485A/485B
Reserved port. Not used.
GND
Grounding wire.