TBM
PILOT’S OPERATING HANDBOOK
850
SECTION 4
NORMAL PROCEDURES
EASA Approved
AMPLIFIED PROCEDURES
Page 4.4.68
Edition 1 -- June 22, 2007
Rev. 10
AMPLIFIED PROCEDURES
SHUT--DOWN (3/3)
Post--MOD70--0335--34 (ESI--2000)
-- ESI--2000 -- NORMAL PROCEDURE
No pilot action required for normal shutdown. The ESI--2000 will shut
down within 5 minutes.
-- ESI--2000 -- MANUAL PROCEDURE
The ESI--2000 can be manually shut down when in the discharge
mode to conserve battery power :
. Remove all aircraft power from the ESI
. Press any key (button) as stated by the on screen message
. Press the M (Menu) button repeatedly until shutdown menu is
shown.
. Press and hold the + (Hold) button until “SHUTTING DN” message
is shown in the upper left corner of the screen.
PIM - DO NOT USE FOR FLIGHT OPERATIONS