TBM
PILOT’S OPERATING HANDBOOK
850
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Page 3.3.8
Edition 1 -- June 22, 2007
Rev. 0
ENGINE FAILURES
3.3 -- ENGINE FAILURES
GOVERNOR REGULATION CONTROL NOT
OPERATING
May indicate a rupture of the linkage of the governor control.
1 -- Continue the flight.
2 -- If Np < 2000 RPM, do not perform a go--around and do not use the
reverse.
In that case, the go--around performance and the reverse efficiency
might be lower than expected. The airplane repair is mandatory before
any other flight.