4.General Specifications
© 2023 China Daheng Group, Inc. Beijing Image Vision Technology Branch 12
Operating Temp.
0°C~+50°C
Storage Temp.
-20°C~+70°C
Operating Humidity
10%~80%
Camera Power
Requirements
12VDC-10% ~ 24VDC+10%
Power Consumption
< 12.7W @ 24VDC
Lens Mount
C
Data Interface
Gigabit Ethernet (1000Mbit/s) or 10G Ethernet (10000Mbit/s)
Dimensions
60mm × 60mm × 54mm (without C mount length)
Weight
340g
Operating System
Win10/Win11 32bit, 64bit OS, 64bit OS is recommended
Programmable Control
Image size, gain, exposure time, trigger polarity, flash polarity
Conformity
CE, FCC, RoHS, GigE Vision, GenICam
1)
Monochrome camera
As shown below, allowed defect numbers in cluster are 2~4 (cluster with 4 consecutive defect pixels in a
row is not allowed (NOK)).
Figure 4-1 MARS-561-207GTM clusters distribution diagram
2)
Color camera
Examples 1: Maximum cluster size within same Bayer color plane is 4, but cluster with 4 consecutive
defect pixels in a row is not allowed.
Figure 4-2 MARS-561-207GTC clusters within same Bayer color plane distribution diagram