The brightness of colours is determined by codes 571 ... 579. 

For code 571 is the lowest brightness and highest for code 579. 
Additionally, code 570 allows control the brightness of light by means of an analogue signal 
0-10V given to input IN B to the driver SPL-3. 
Codes 570 ... 579 described in the instructions point 2.4. 
 

The above-described properties of the driver SPL-3 in RANDOM mode allows control of 

the  large  diversity  of  LEDs.  With  a  lot  of  drivers  SPL-3,  you  can  configure  each  one 
differently to give the effect of diversity in color and brightness of individual points of light. 
 

RANDOM  mode  also  provides  a  smooth  color  transitions.  After  entering  code  500  the 

driver's SPL-3 RANDOM mode will change colors in a smooth manner over the entire range 
of color (palette is irrelevant or range of colors). 

 

During  a  smooth  change  of  color  in  RANDOM  mode,  there  also  works  features  speed 

control and brightness changes, the work described above codes 561...569 and 571...579, and 
560 and 570 codes to control analog 0-10V at the inputs IN A and IN B SPL-3 driver. 
 
 

3.3.1

 

Example configuration of the controller SPL-3 for RANDOM mode. 

 

553 - RANDOM mode operation 
019 - chosen color palette number 0 and the color range from 1 to 9 – see tab.3. 
650 - no white balance correction 
561 - rate of change of color at approximately 40 sec 
576 - slightly reduced brightness

 

 

These five codes must be entered into the controller SPL-3, to work in a desired manner. 
The order of input codes is optional. 
 
 

3.3.2. Example configuration of the controller SPL-3 for RANDOM mode. 

 

553 - RANDOM mode operation 
425 - chosen color palette number 4 and the color range from 2 to 5 – see tab.3. 
 

(red, blue, orange, violet)

 

650 - no white balance correction 
566 - rate of change of color at approximately 1 sec 
579 - the maximum brightness 

 

These five codes must be entered into the controller SPL-3, to work in a desired manner. 
The order of input codes is optional. 
 

Summary of Contents for SPL-3

Page 1: ...STRIP DRIVER works alone or controlled by DMX 512 2 buttons 2 analogue signals 0 10V MANUAL DAGON Company 64 100 Leszno Jackowskiego 24 Street tel 48 664 092 493 dagon iadagon pl www dagonlighting co...

Page 2: ...ration of the controller SPL 3 for RANDOM mode 18 3 4 DMX COLOR 1 mode 19 3 5 DMX RGB mode 19 3 6 DMX MIX COLOR 1 RGB mode 20 3 7 Additional information about the SPL 3 controller operation in all mod...

Page 3: ...rticular modes of driver SPL 3 work are described in the further parts of manual Fig 1 Main draft and dimension of SPL 3 Inputs function IN A and IN B depends on mode of SPL 3 work for example IN A DM...

Page 4: ...the external controls buttons PLUS and CODE which user can connect to the inputs control IN A and IN B A prerequisite for the operation of external buttons and the buttons CODE PLUS is connected to o...

Page 5: ...t of code press CODE button one more time Yellow diode light off and the green diode will light on the code is already accepted After entering the code SPL 3 goes to regular work to control the diodes...

Page 6: ...first digit of DMX address is 0 to 5 Than once blink the yellow diode which is the signal for reading the second digit Viewing second digit of address DMX 512 Green diode will blink as many times as...

Page 7: ...MER OFF function DIMMER is off in DMX mode 621 DIMMER ON 1 function DIMMER is on 0 min 255 max brightness 622 DIMMER ON 2 function DIMMER is on 0 max 255 min brightness 630 STROBO OFF function STROBO...

Page 8: ...the reader will find in 3 3 point The RANDOM mode is connected with codes 560 569 and 570 579 Codes 560 569 determine speed of the colour changes the codes 570 579 regulate the brightness of LED diode...

Page 9: ...hannel DMX 512 When the signal DMX 512 increased for code 621 the brightness of LED will also increased When the signal DMX 512 increased for code 622 the brightness of LED will decreased When functio...

Page 10: ...MX 512 signal controller response in defined code entered The reemergence of DMX 512 signal at the inputs IN A and IN B causes an immediate return to the control outputs CH1 CH2 CH3 data from the rece...

Page 11: ...RIGHTNESS or COLOR cause fluently extinction of all LED diodes It is possible to set the delay time of turning off the lights while the short pressing the COLOR button If for various reasons the user...

Page 12: ...keys pressing the BRIGHTNESS and COLOR D1 D2 any low power diodes for example the automatic color change after the hold button no 3 Ad Fig 3B The Zener diode limits the voltage at the inputs IN A and...

Page 13: ...automatic color changing After a simultaneous hold on buttons BRIGHTNESS and COLOR for more than 1 second the SPL 3 driver starts automatic smoothly colour changes Colors will change in the same way a...

Page 14: ...s SPL 3 controller BRIGHTNESS and COLOR Lp Activity of steering buttons SPL 3 reaction Short press of buttons BRIGHTNESS or COLOR smoothly fluently turn on turn off LED RGB diodes 1 Short press of but...

Page 15: ...matic and fluent color changes as it is in BUTTONS mode of work Changes the voltage from 10V to 15V regulate the speed of color changes form the slowest till the fastest blinking effect Brightness lev...

Page 16: ...pink orange blue red light blue white yellow violet 4 black light blue red blue orange violet yellow pink green white Palette selection is made by entering the first digit code from 000 499 digits 0...

Page 17: ...th change of color in RANDOM mode there also works features speed control and brightness changes the work described above codes 561 569 and 571 579 and 560 and 570 codes to control analog 0 10V at the...

Page 18: ...of the LEDs connected to the SPL 3 Figure 5 Included light dependent resistor should be exposed to daylight When night falls light dependent resistor resistance increases and the voltage divider at th...

Page 19: ...without function DIMMER an active channel for the STROBE function is DMX control channel again after the color of glow Thus SPL 3 driver working in DMX COLOR 1 mode one can use the COLOR of 1 2 or 3 c...

Page 20: ...unctions DIMMER and STROBE which will activate the channel number 5 and 6 The number and sequence of assignments to channels DMX controller features SPL 3 in DMX MIX mode is as follows 4 channel COLOR...

Page 21: ...nical data Power supply 9 24V DC Current consumption without load max 30mA Number of PWM outputs 3 CH1 R CH2 G CH3 B Output type OC open collector N MOSFET Polarization of outputs common plus common a...