Page 21
Hydraulic System Troubleshooting, Testing and
Adjustment
Return to Master Table of Contents
Compare recorded values with output shown in the P-Q curve in the specifications section of this book.
If test results do not measure up to specified values, pump output tests can be repeated using different
control levers. Recheck front pump operation while stroking the bucket cylinder out lever, and the rear
pump by actuating the swing control lever.
NOTE:
When testing bucket and swing functions, read maximum flow tests at 320 kg/cm
2
(4,550
psi), not 350.0 kg/cm
2
(4,978 psi).