background image

Radiographic image scanner EAGLE.PS

 

77

 

 

UNFORESEEN- TROUBLESHOOTING 

 

Should you find an operation problem, follow the instructions below to check and repair the 
problem, and / or contact your dealer. 

 

Unforeseen 

Likely cause 

Solutions 

 Inoperative Equipment. 

  Disconnected power plug 

  General Power switch off. 

  Power shortage in the network 

  Plug power plug into outlet. 

  Turn on power switch. 

 

Wait for power network 
normalization 

 

Equipment switches off as 
soon as it gets started. 

 Cables or plug not properly 

connected. 

 Hardware failure. 

 Low voltage in power supply 

network. 

 Check power cables for proper 

wiring. 

 

Request a visit of an 
authorized DABI ATLANTE 
technician. 

  Check the local voltage. 

 Status or Operation LEDs fail 

to light. 

 LED failure. 

 

Request a visit of an 
authorized DABI ATLANTE 
technician. 

 Too much noise after turning 

on the equipment 

 If the noise persists for more 

than 30 seconds, there is a 
problem with the motor. 

 

Request a visit of an 
authorized DABI ATLANTE 
technician. 

 EAGLE.PS  image  retrieval 

software does not recognize 
the equipment 

 

The Equipment is not 
connected. –The Equipment is 
not connected to the computer.

 Computer does not recognize 

the EAGLE.PS equipment. 

 Hardware failure. 

  Turn on the equipment. 

 Check the USB connection of 

the equipment to the 
computer. - USB Driver (FTDI) 
is not installed or is inactive. 

 Check the USB cable. - Inform 

DABI ATLANTE technical 
support 

 Equipment does not respond 

when inserting a phosphorous 
plate. 

 EAGLE.PS did not complete 

the startup process. 

 Wait 20 - 30 seconds to finish 

boot. 

Summary of Contents for EAGLE.PS

Page 1: ......

Page 2: ...d Km 53 450m Cx Postal 782 CEP 14097 500 Ribeir o Preto S P Brasil Telephone 55 16 2102 5000 Fax 55 16 2102 5001 CNPJ 55 979 736 0001 45 Technical Manager Ricardo J Ravaneli CREA SP 5060714523 ANVISA...

Page 3: ...onditions under normal use 71 Cautions and Attention during equipment installation 72 Cautions and Attention during equipment use 72 Cautions and Attention after equipment use 72 Cautions and Attentio...

Page 4: ...graphic images scanner Business Name EAGLE PS Model EAGLE PS Brand DABI ATLANTE Equipment Indication This equipment is for dental use only and should be used and handled by a qualified person properly...

Page 5: ...phosphorous plate should be inserted into the input compartment of the equipment to read the image data Dental imaging software performs the interface between the Eagle PS system and the user allowin...

Page 6: ...ed Therefore when purchasing the product check the technical compatibility between equipment coupling and accessories 01 Eagle PS Body 02 Inlet enclosure 03 On Off key 04 Green LED indicator On Off 05...

Page 7: ...e Phosphorous Plate An error occurred Blinking alter nating Initializing the equipment Operating LED s Status Indication Attention If the equipment shows any abnormality check whether the problem is r...

Page 8: ...For periapical examination for pediatric use b For bitewing examination for pediatric use c For periapical examination for adult use d For bitewing examination for adult use 03 Protective covers For e...

Page 9: ...ration mode Continuous Protection against harmful penetration of water or particulate matter IPX0 Net weight 5 3 Kg Dimensions A 285 mm x L 175 mm x P 240 mm General Framing according to Anvisa Class...

Page 10: ...d with the arrow side up Determines that the packaging must be stored or transported with light protection Determines that the packaging must be stored and transported carefully it should not suffer f...

Page 11: ...scanner EAGLE PS 11 TECHNICAL SPECIFICATIONS Product Symbology Use only one time Do not reuse It is mandatory to use protective gloves Dangerous electrical voltage Laser alert USB connection Erase pho...

Page 12: ...e diagnostic ability of the x ray examination Operational system The system will work on the following operating systems Windows 7 32 and 64 bits or higher Mac OS X v10 8 to v10 9 General requirements...

Page 13: ...the Software DVD ROM into the PC DVD ROM drive 2 The Select Language Configuration dialog box appears Select the installation language and click OK 3 Check if this is the version and software to be in...

Page 14: ...elect type of installation Available installation types Client Where only the application is installed Suggestion for network clients In this case you will need to Include the IP address of the databa...

Page 15: ...lled correctly see section Appendix B Windows Firewall Configuration Server Mode If there is an error in the database installation the process will be aborted and must be restarted If an error occurs...

Page 16: ...ollow the steps below to properly install the product Eagle PS is equipped with 2 connecting ports located on the rear of the equipment 24V b Connection Provides power for operation of the equipment U...

Page 17: ...rk this side as plate size 0 1 2 3 or 4 and the text Back or Reverse Working with Phosphorous plates The plates are sensitive to physical damage and if necessary must be replaced periodically Pay atte...

Page 18: ...protective cover is a disposable product it should not be used once more Select the appropriate positioner for the region of Interest and the size of the phosphorous plate Perform the required X ray...

Page 19: ...monitoring screen After the image retrieval is complete the phosphorous plate is automatically switched off and expelled through the front opening Points of observation No other phosphorous plate sho...

Page 20: ...de in the Image Type field The system provides the following actions Counter clockwise rotation Represents the rotation functionality in the counter clockwise direction on the Retrieved image Clockwis...

Page 21: ...e Plate PSPL and proceed with the insertion of phosphorous plate into the equipment To erase a phosphorous plate through the equipment press the Erase button located in the center of the main panel Wa...

Page 22: ...DICOM Images It is possible to compare selected images in groups of 2 3 or 4 images To make this comparison it is necessary to select between 2 and 4 images in the place where the thumbnails of the i...

Page 23: ...arison of Three Images Figure 7 Comparison of Four Images Printing DICOM Images The selected images can be printed with the changes that were made To perform the print out the user must click the Prin...

Page 24: ...st can request to print the DICOM header I e all DICOM tags forming the selected image Figure 9 Confirmation Pop up for Printing the Dicom Header Image printing follows the standard below with or with...

Page 25: ...times the image size for more or less Figure 12 Transformation Toolbar Zoom For Rotation application counter clockwise or clockwise the user must select the rotation icons located in the Toolbar Figu...

Page 26: ...n the most white target and the most dense black that can be obtained in the image Apply Blur This filter softens the image making it less sharp reducing noise Apply Sharpen Highlight This filter enha...

Page 27: ...ible to perform angle measurements between two consecutive lines The unit of measurement shall be degrees to the accuracy of two decimal places Calibrate Measurement This feature enables to calibrate...

Page 28: ...user login on this system In this field only text without special characters is allowed Password Represents the user password on this system This field accepts alphanumeric data and there is no restr...

Page 29: ...utput as shown below Figure 22 Confirmation pop up to exit the system System logoff The System logoff procedure allows the user to disconnect and later he can connect with another user name without ne...

Page 30: ...les associated with the current user Date and time of last user s current visit Features available Search and Include new Patient Search and Include New Agreement Search and Include new User Other Opt...

Page 31: ...o search the users registered in the system Figure 26 User Search Screen Users search is available through the following paths Home System Screen Search button User Menu Item Search User The following...

Page 32: ...user belongs If the user has more than one profile they are displayed separated by a semicolon Status Represents user status such as active or inactive View relevant information concerning searched u...

Page 33: ...f the photo uploaded in full size by the user Remove Photo Action referring to the deletion of the user s photo User Represents the name of the user that will be used to access the system Password Rep...

Page 34: ...mail settings Use Default E mail If selected the system will use standard operating system e mail Ex Outlook Manual Setup If selected the system will enable the following fields for Manual Setup E mai...

Page 35: ...en choosing a default mail server the system automatically populates the following fields Outgoing Server SMTP Port SMTP Encrypted Connection and Encryption It is only necessary to inform the user s e...

Page 36: ...the alteration of the User Name Login and the Status active inactive and Profile The user profile cannot be modified for a higher value profile For example Modify from Dentist to Administrator or from...

Page 37: ...IPMENT OPERATION View User The view screen allows the operator to see details of the user registered in the system View of user data is made available through the following path View icon in user sear...

Page 38: ...form editing the profiles as well as the permission that may or may not be associated with the profile Editing a user profile is available through the following path User Menu Item Setup Profile Figur...

Page 39: ...us of the application and all actions with the x ray images are made from them There is the possibility of associating one or more Dentists with this Patient making them responsible for their images S...

Page 40: ...to the new image retrieval screen for the selected patient Forwards to the New Image Import screen for the selected patient View all images of selected Patient Table 2 Actions for Patient Table Remar...

Page 41: ...48 Agreement Number Represents the patient covenant portfolio number Completing it becomes mandatory when the Agreement field is filled in Dentist Represents the user s name with profile Dentist which...

Page 42: ...or to edit the data of a patient already registered in the system Figure 38 Patient Editing Screen Patients editing is available through the following path Edit icon in Patient s search result table A...

Page 43: ...Radiographic image scanner EAGLE PS 43 Patient with saved odontogram...

Page 44: ...0 Patient View Screen The Patients view is available via the following path View icon in Patient s search result table Patient icon on the Patient Image Viewing screen Figure 41 Patient view bar Impor...

Page 45: ...ise rotation feature in the image Clockwise rotation Represents the functionality of Clockwise rotation in the image Auto Adjustment Represents the automatic adjustment feature in the image View Image...

Page 46: ...ith Zoom Zoom in Zoom Out and Full Screen Manipulate Image Represents the image manipulation application through Options are Rotation Anti Clock Clockwise rotation Horizontal Mirror and Vertical Mirro...

Page 47: ...e exclusion question is confirmed the image s will be deleted It is checked during image exclusion if it has Diagnosis If it has you will not be able to delete it Remarks In the Images tab the system...

Page 48: ...NT OPERATION Figure 46 Image Properties Confirmation Pop up Modify Patient If you wish to modify the Patient owner of the image a new Patient must be searched according to the image below Figure 47 Pa...

Page 49: ...Agreement previously registered in the system Status Represents the status of the registered Agreement Possible Options are Active Inactive and All By clicking on the search icon the results are popul...

Page 50: ...Agreement on the Home Screen System Menu Agreement New Agreement Agreement Search New Agreement The following field for entering the Agreement is displayed Name Represents the name of the Agreement Re...

Page 51: ...ill be displayed with a red highlight in the patient editing Exclude Agreement The Agreement exclusion screen allows the Exclude operator an Agreement registered in the system The exclusion of Agreeme...

Page 52: ...at the text can be inserted For the notes mentioned above it is possible to make the following adjustments of Source Configuration that allows the operator to select font font style and size before en...

Page 53: ...e rotation of the image with the angle variation between rotations of 90 Horizontal Mirror Represents the Mirroring of the image which reverses the same in the horizontal direction Vertical Mirroring...

Page 54: ...h the default being 50 Apply Gamma Represents the split luminosity INDEX of the particles c of the image The gamma variation should be between 0 and 100 points with the default being 20 Apply Color Sh...

Page 55: ...w location and in parallel the new measured value will be displayed Hide By clicking on this icon the system will hide the Measurements made in the image that is it will not display the Measurements t...

Page 56: ...Patient x ray Include Diagnosis The insertion screen allows the operator to include a new Diagnosis in the system for the selected image Figure 58 Diagnosis Screen Diagnosis of an image is available t...

Page 57: ...e viewed in larger size with the changes and adjustments made to the image by clicking the View Image icon If the operator wishes to perform Diagnosis on images with manipulations notes filters or mea...

Page 58: ...he following functionalities for export Export Location Represents the location where the Images will be exported Example Local Disk HD Pen Drive etc Location can be selected With the Select Directory...

Page 59: ...erator to send an image in JPEG PNG or DICOM format the image of the complete periapical scheme the periodontal documentation scheme or Diagnosis of the selected image Sending E mail is made available...

Page 60: ...ete an attachment The supported versions of Outlook Windows default e mail are 2007 and 2013 Internet access is required so that emails can be sent The uploaded images have the default file name Singl...

Page 61: ...arks The system validates the dates Initial and Final so that they are filled in valid formats and in correct order i e Final after Initial date The log file can be exported to a text file and saved t...

Page 62: ...be able to recover an image a new x ray should be performed Phosphorous plate erasure is available through the following path Menu Erase plate Home Screen Other Options Erase plate Remarks If the use...

Page 63: ...Represents the choice of default operating system email usage When this option is selected the system automatically sends the e mail using the default operating system email program Manual Configurat...

Page 64: ...on possibilities Header Logo brand Represents the logo brand of the clinic to be loaded from a file Possible Options are Upload Photo View Photo and Remove Photo Clinic Name Represents the name of the...

Page 65: ...or zooming located back to the initial aspect ratio of the viewer Remarks Next image When this action is triggered the system will display the image following the current one in the periodontal scheme...

Page 66: ...View Image Full Periapical This is the Full Periapical Full Image view screen Figure 70 Full View Periapical Screen The system displays images Retrieved according to the Full Periapical standard Right...

Page 67: ...lt image of the design The Image Zoom Manipulate Image Perform Calibration Measure Image Annotate Image and Apply Settings and Filters will be disabled ie the operator will not be able to apply These...

Page 68: ...to writable media send by e mail and issue Diagnostics Figure 72 Complementary Documentation View Screen In addition to periapical images Complementary Documentation also displays the following image...

Page 69: ...mages This feature is responsible for Comparison of two or more images selected Dividing the screen in 2 to 4 equal parts for visualization Figure 73 Image Comparison Screen 2 images Figure 74 Image C...

Page 70: ...lable at Configure Menu Perform Backup The system displays the following message The last backup performed was at last backup date and time Confirm execution of a new backup As shown in Figure 76 Figu...

Page 71: ...the successful backup restore message the system will be automatically closed to complete the process of importing the backup data Odontogram This is the Odontogram view screen It enables the operator...

Page 72: ...Owner s Manual 72 The Diagnosis icon will be disabled when entering this tab because the operator can access the Diagnosis by clicking on the tooth position...

Page 73: ...range 21 C to 26 C Operating relative humidity range 30 to 75 Atmospheric pressure range 700 hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment will maintain its sa...

Page 74: ...the equipment which could cause short circuits The EAGLE PS equipment was developed only for the retrieval of X ray images periapical sizes 0 1 2 or 3 This equipment is not suitable for monitoring pat...

Page 75: ...sodium hypochloride isn t recommended because they may damage the equipment General cleaning Important To carry out cleaning or any type of maintenance make sure that the equipment is disconnected fr...

Page 76: ...as any abnormalities check whether the problem is related to any of the items listed in the unpredicted item situation cause and solution If the problem cannot be solved switch off the equipment and r...

Page 77: ...k the local voltage Status or Operation LEDs fail to light LED failure Request a visit of an authorized DABI ATLANTE technician Too much noise after turning on the equipment If the noise persists for...

Page 78: ...em An error occurred while accessing the photo or a corrupted image If the problem persists contact the System Administrator The system usually displays this Message when the system tries to access a...

Page 79: ...registered in the system The system usually displays this Message when the operator requests to add edit a user by filling the field CPF for users with profiles of technician dentist and administrato...

Page 80: ...ields must be filled in The system typically displays this Message when the required user and password fields are not filled in the system login screen All required fields must be filled in Invalid Us...

Page 81: ...running a feature on the profile pop up screen Remain on the profile setup screen until you finish the desired functionality Your profile does not have access to this feature If in doubt contact the S...

Page 82: ...nt The system usually displays this Message when the operator selects no dentists to associate with the Patient Select at least one dentist to associate with the Patient Patient patient name cannot be...

Page 83: ...have adequate profile Choose a new dentist The system usually displays this Message when the operator selects a dentist that for some reason has ceased to have the dentist profile and became administ...

Page 84: ...mmunication with the database The image cannot be excluded because it has a diagnosis associated with it The system typically displays this Message when the operator requests to delete an image that h...

Page 85: ...hile a feature is running on the Diagnosis screen Stay on the diagnostic screen until the desired functionality is complete Export to Recordable Media Message Error or warning grounds Solution There a...

Page 86: ...ttings and or if you have a locking mechanism that is preventing the application from communicating with the internet and redo the procedure of sending email There are unfilled mandatory fields The sy...

Page 87: ...lem persists contact the System Administrator The system usually displays this Message when the operator removes all attached files in the e mail that will be sent Reestablish communication with the d...

Page 88: ...t busy Wait until current process is finished The system usually displays this Message when the operator requests to erase the phosphorous plate however the equipment is performing another process Wai...

Page 89: ...cally displays this Message when the operator attempts to select a user that does not have the Dentist profile as the Requestor The operator must select a user having Dentist profile Initializing equi...

Page 90: ...displays this Message when the operator does not insert the phosphor plate into the equipment within 120 seconds Insert the phosphor plate into the equipment within 120 seconds after the retrieval re...

Page 91: ...ation with the database There is an error in the medical image type If the problem persists contact the System Administrator The system usually displays this Message when it detects an error in the im...

Page 92: ...hen there is no connection to the database Reestablish communication with the database There was an error accessing the file If the problem persists contact the System Administrator The system typical...

Page 93: ...FINAL CONSIDERATIONS Among the care that you must follow with your equipment the most important is when it comes to replacement parts To ensure the life of your device replace only with genuine DABI...

Page 94: ...8 does not allow installation of drivers not certified by Microsoft so to install the WIA driver in Windows 8 it is necessary to disable verification by the operating system as follows 1 In Windows 8...

Page 95: ...Radiographic image scanner EAGLE PS 95 APPENDIX A WIA WINDOWS IMAGE AQUISITION 3 Choose ADVANCED OPTIONS 4 Choose INITIALIZATION SETTINGS...

Page 96: ...GE AQUISITION 5 Click RESTART 6 When restarting the Options will be displayed enter option 7 Disable Drivers Subscription imposition Therefore the driver signature will be disabled At the end of the a...

Page 97: ...ge retrieval is possible through the Windows Image Acquisition WIA standard enabling the EAGLE PS equipment to communicate with other software running as a scanner The default installation of EAGLE PS...

Page 98: ...ed to the server ATTENTION Client mode installation must be done after performing this procedure on the server Note The procedure was performed with Windows 7 1 To open Windows Firewall click the Star...

Page 99: ...GURATION MODO SERVIDOR Click port for the rule type move forward TCP Enter 5431 in specific local ports move forward Allow connection move forward move forward name EAGLE PS conclude 5 After completin...

Page 100: ...Owner s Manual 100...

Page 101: ...Radiographic image scanner EAGLE PS 101...

Page 102: ......

Reviews: