INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
45
Instruction manual edition 1 for EP104 version 4.08
No.
Name
Range
Factory Setting Ref.
page
L120*
Position of motor 2, viewed from the motor side
0-2
2
0
Disabled
1
Left
2
Right
L121*
Position readout, motor 2
000-360 degrees
L122*
Limit for open position, motor 2
145-330 degrees
260
L123*
Limit for closed position, motor 2
015-180 degrees
90
L124*
Limits when speed will decrease during the opening
movement, motor 2.
(Only when using a frequency converter)
0-99 degrees
L125*
Limits when speed will decrease during the closing
movement, motor 2.
(Only when using a frequency converter)
0-60 degrees
45
L126*
Degrees for limited opening, motor 2
0-200 degrees
45
L127*
Degrees for the disconnection of safety edges, load
guard and photocells from the end of the closing
movement, motor 2 in combination with C436,
C341 and C448
0-30 degrees
0
L128*
Degrees for the disconnection of vehicle loops
from the end of the closing movement, motor 2 in
combination with d141 or d241
0-45 degrees
0
L311
Time readout for motor 1
00.1-99.9 seconds
L312** Set time for motor 1
00.1-99.9 seconds
00.1
L321
Time readout for motor 2
00.1-99.9 seconds
L322** Set time for motor 2
00.1-99.9 seconds
00.1
* = Only displayed if L002 are set to 1.
** = Only displayed if L001 and/or L002 are set to 2 or 3.
Summary of Contents for EP104