INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
44
Instruction manual edition 1 for EP104 version 4.08
• Limit switch, L-channels
No.
Name
Range
Factory Setting Ref.
page
L001
Choice of limit switch type for motor 1
0-3
0
0
Disabled
1
Encoder
2
Limit switch
3
Time
4
Hold-to-run without limit switches. NOTE! Only one half at a time can be run. C033 must be set to 5.
L002
Choice of limit switch type for motor 2
0-3
0
0
Disabled
1
Encoder
2
Limit switch
3
Time
4
Hold-to-run without limit switches. NOTE! Only one half at a time can be run. C033 must be set to 5.
L110*
Position of motor 1, viewed from the motor side
0-2
1
0
Disabled
1
Left
2
Right
L111*
Position readout, motor 1
000-360 degrees
L112*
Limit for open position, motor 1
145-330 degrees
260
L113*
Limit for closed position, motor 1
015-180 degrees
90
L114*
Limits when speed will decrease during the opening
movement, motor 1.
(Only for frequency converter and encoder)
0-99 degrees
L115*
Limits when speed will decrease during the closing
movement, motor 1.
(Only for frequency converter and encoder)
0-99 degrees
L116*
Degrees for limited opening, motor 1.
0-200 degrees
45
L117*
Degrees for the disconnection of safety edges, load
guard and photocells from the end of the closing
movement, motor 1 in combination with C436,
C341 and C448
0-30 degrees
0
L118*
Degrees for the disconnection of vehicle loops
from the end of the closing movement, motor 1 in
combination with d141 or d241.
0-45 degrees
0
* = Only when L001 are set to 1
Summary of Contents for EP104