INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
36
Instruction manual edition 1 for EP104 version 4.08
Safety edge
No.
Name
Range
Factory Setting Ref.
page
S
C101 Safety edge acknowledgement SE.C1
0 – 1
0
0
Disabled
1
Enabled
S
C102 Function of output for external protection
0 – 4
0
0
Check disabled, open output, setting of C113, C123, C133, C143, C343, P643 is disabled.
1
Closed to GND on activation, normally open.
2
Closed to +24 VDC on activation, normally open.
3
Open on activation, normally closed to GND.
4
Open on activation, normally closed to +24 VDC.
S
C103 Function of safety edge input during test of
external safety edge unit
1 – 2
1
1
Low resistance during test
2
High resistance during test
S
C104* Connection and safety edge function
1 – 2
1
1
SE.C1 or SE.C2 can be connected to either motor 1 or motor 2.
SE.O1 or SE.O2 can be connected to either motor 1 or motor 2.
Both safety edges reverse/stop an active motor
2
SE.C1 and SE.O1 must be connected to motor 1
SE.C2 and SE.O2 must be connected to motor 2
The safety edge function is attached to the motor concerned
C105
Halved speed or activated safety edge
(Only when using a frequency converter)
0 - 1
0
0
Disabled
1
Active
S
C111 Selects function for safety edge SE.C1
0-2
2
0
SE.C1 disabled
1
Limits according to set value in C115
2
Fixed limits between 5 kohm and 15 kohm
S
C112 Reverse/stop with activated safety edge SE.C1
(KSS)
1 - 2
1
1
Reverse
2
Stop
S
C113 Control of external protection connected to SE.C1 0 - 1
1
0
No check
1
Test of protection connected to SE.C1
C114
Reading impedance SE.C1
00.0-99.9 kΩ
S
C115 Setting impedance value for safety edge SE.C1
Set to 1 only at C111.
1.0-9.9 kΩ
8.2
* = Only displayed if EP104-2