INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
52
Instruction manual edition 1 for EP104 version 4.08
P675
Opening via input after activation during set time,
input will not open the barrier until it has been
activated for the set time.
0.0-9.9 seconds
0.0
P680
Keep opened
0 - 2
0
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P690
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P660 is set to open, and passes the signal on to the remote door
P696
Blocking disabled for local and remote doors. Works
only with a constant signal.
0 - 1
0
0
Disabled
1
Active
P698
Automatic closing disabled for remote door Only
works if there is a constant signal
0 - 1
0
0
Disabled
1
Active
Summary of Contents for EP104