Error
code
Meaning
Possible cause
E912
Incorrect checksum in flash memory
Contact FAAC Nordic AB.
E913
Memory error in RAM
Contact FAAC Nordic AB.
E914
Memory error in EEPROM
Contact FAAC Nordic AB.
E915
Incorrect EEPROM version
Contact FAAC Nordic AB.
E916
Internal test not completed in time
Contact FAAC Nordic AB.
E917
Incorrect order of execution
Contact FAAC Nordic AB.
E918
All error codes deleted due to an internal fault
E921
Contactor for motor 1 activated before the
previously activated contactor has been deactivated.
Contact FAAC Nordic AB.
E922
Contactor for motor 2 activated before the
previously activated contactor has been deactivated.
Contact FAAC Nordic AB.
E931
Stop at the same time as an open/close operation.
E932
Open operation at the same time as a close
operation.
E941
Motor 1 running in the wrong direction according
to the encoder setting.
Check that channel L110 is set to the correct side. Check the
motor is running in the right direction.
E942
Motor 2 running in the wrong direction according
to the encoder setting.
Check that channel L120 is set to the correct side. Check the
motor is running in the right direction.
E943
No movement encoder 1
Check connection to the encoder.
E944
No movement encoder 2
Check connection to the encoder.
E961
SE.C1 did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
E962
SE.C2 did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
E963
SE.O1 did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
E964
PHOTO did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
E965
Photocell did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel P643 to 0.
E966
SE.O2 did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C143 to 0.
E971
SE.C1 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
E972
SE.C2 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
E973
SE.O1 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
E976
SE.O2 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C143 to 0.