This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted, while the blowing air is
switched on for transferring the label onto product.
Value range: 0 … 2500 ms
Step size: 10 ms
Default: 100 ms
This parameter is only active if the operating mode 'blow on' and
mode 'apply-print' are selected.
Waiting position up:
In cyclic mode the pad with the printed label waits in the labelling
position near the dispense edge of printer for the external start signal.
Waiting position down:
In cyclic mode the printed label is transported to the labelling position
at the end of a cycle.
So the next cycle begin with blowing up the label.
This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted while the roll on pad is
stopped in labelling position.
Value range: 0 … 5000 ms
Step size: 10 ms
Default: 0 ms
This parameter is only active if the operating mode 'blow on' and 'roll
on' are selected. The time period can be adjusted for the cleaning
period of pad after application procedure.
Value range: 0 … 2500 ms
Step size: 10 ms
Default: 100 ms
Moving up and down of pad.
If the pad does not reach the corresponding final position within the
set time, then an error message appears ('final position above' at
moving up and/or 'final position below' at moving down).
Value range: 0 … 5000 ms
Step size: 10 ms
Default: 0 ms
Stroke adjust
The arrester can be adjusted and the stroke speed can be set. The
pad makes a stroke movement and return again to the basic position
after reaching the lower end position.
Blow time
Waiting position
Roll on time
Cleaning time
Stroke timeout
Test functions