Power line voltage and power line frequency: See type plate
Allowable tolerance of power line voltage:
+6% …
−
10% of nominal value
Allowable tolerance of power line frequency:
+2% …
−
2% of nominal value
Allowable distortion factor of power line voltage: <=5%
In case your net is infected (e.g. by using thyristor controlled
machines) anti-interference measures have to be taken. You can use
one of the following possibilities:
•
Provide separate power supply to our printers.
•
In case of problems please connect capacity-decoupled isolation
transformer or similar interference suppressor in front of our
printers.
Emitted interference according to EN 61000-6-3: 2007
industrial sector
•
Interference voltage to wires according to EN 55022/AC: 2011-10
•
Interference field power according to EN 55022/AC: 2011-10
•
System perturbation according to EN 61000-3-2: 2014-08
•
Flicker according to EN 61000-3-3: 2013-08
Immunity to interference according to EN 61000-6-2: 2008
industrial sector
•
Stray radiation against discharge of static electricity according to
EN 61000-4-2: 1995
•
Electromagnetic fields according to EN 61000-4-3: 2002
•
Fast transient burst according to EN 61000-4-4: 2004
•
Surge according to EN 61000-4-5: 1995
•
High-frequency tension according to EN 61000-4-6: 2014-02
•
Magnetic field with energy frequency according to EN 61000-4-8:
1993
•
Voltage interruption and voltage drop according to EN 61000-4-
11: 2004
NOTICE!
This is a machine of type A. This machine can cause
interferences in residential areas; in this case it can be required
from operator to accomplish appropriate measures and be
responsible for it.