Function Menu
Spectra II
50
Operating Manual
08.17
6.8.4 Transfer Ribbon
Ribbon prior warning:
Before the end of transfer ribbon, a signal is
send by the control output.
Ribbon prior warning diameter:
Setting of transfer ribbon advance
warning diameter.
In case you enter a value in mm then a signal appears via control
output when reaching this diameter (measured at transfer ribbon roll).
Ribbon prior warning mode:
Warning:
When reaching the transfer ribbon advance warning
diamter, the corresponding I/O output is set.
Reduced print speed:
Speed on which the printing speed is to be
reduced.
Error:
The printing system stops when reaching the transfer ribbon
advance warning diameter with the message 'too less ribbon'.
Speed:
Setting of the reduced print speed in mm/s. This can be set in
the limits of the normal print speed.
Roll diameter:
Indication how much transfer ribbon is still on the
transfer ribbon roll. For a correct display some labels must be
reprinted.
Time left:
Indication during a current print order, how long it can be
printed with the existing transfer ribbon.
6.8.5 I/O Status
Relevant results are counted and registered in RAM memory. The
protocole get lost after switching off the device.
PrtStrtIntsReal
= Real Interrupts
The start input impulses are counted directly at the Interrupt.
PrtStrtIntsDebounced
= Debounced
The start input impulses that are longer than the set debounce time
are counted. Only these start impulses can lead to a print. If a start
impulse is too short, no print is released. This is recognized by the fact
that RInt is counted, Dbnc not.
PrtStrtIntsNoPrint
= Not Printed
The debounced start input impulses that have not lead to a print are
counted. Causes: no active print order, print order stopped (manually
or because of an error) or the printing system ist still active with the
processing of a print order.
PrtStrtReset
= The counters are reset.
PrtStrtTime
= Measured length of the last start impulse in ms.
Prewarning
Current diameters