Chapter 6: Service and Maintenance
Replacing the Ignitor
Before You Begin
CAUTION
Both the igniter and flame probe can still be hot if the heater was in operation. Allow
heater to cool completely before performing any maintenance.
• Disconnect all power sources to the heater.
• Turn off the gas supply.
To remove the ignitor:
1. Loosen the two screws (2) attaching the igniter/flame probe mounting bracket (1) to the burner duct.
2. Disconnect the igniter and flame probe from the control box.
3. Slide the igniter/flame probe mounting bracket (1) off of the screws to remove the probe assembly.
4. Remove the the igniter (3) from the igniter/flame probe mounting bracket (1) by removing the screw
(2).
To install the ignitor:
5. Install the igniter (3) to the igniter/flame probe mounting bracket (1) using the screw (2).
6. Slide the igniter/flame probe mounting bracket (1) onto the screws on the burner duct.
7. Connect the igniter and flame probe to the control box.
8. Tighten the two screws (2) to install the igniter/flame probe mounting bracket (1) to the burner duct.
Figure 6-11
Ignitor
1 —
Probe mounting bracket
2 —
Screw
3 —
Ignitor
4 —
Flame sensor
PNEG-2091
VariFlame™ Heater
49
Summary of Contents for VariFlame VF-16-ONG
Page 4: ...NOTES 4 PNEG 2091 VariFlame Heater...
Page 28: ...Chapter 4 Installation Figure 4 6 VariFlame EDGE wiring diagram 28 Pneg 2091 VariFlame Heater...
Page 29: ...Chapter 4 Installation Figure 4 7 VariFlame EDGE schematic PNEG 2091 VariFlame Heater 29...
Page 30: ...Chapter 4 Installation Figure 4 8 Dipswitches 30 PNEG 2091 VariFlame Heater...
Page 31: ...NOTES PNEG 2091 VariFlame Heater 31...