Chapter 6: Service and Maintenance
Figure 6-12
Ignitor
1 —
Probe mounting bracket
2 —
Screw
3 —
Ignitor
4 —
Flame sensor
Replacing the control board
Before You Begin
• Disconnect all power sources to the heater.
• Turn off the main gas supply.
To remove the control board:
1. Remove the control box lid (8) by removing the four screws (7).
2. Disconnect all field wired connections from the board.
3. Disconnect all heater electrical components from the board.
4. Remove all screws connecting the board to the control box.
5. Remove the control board.
To install the control board:
6. Connect the control board to the control box using five screws (7).
7. Connect all heater electrical components. (See wiring diagram for more details.)
8. Connect all field wiring.
9. Install the cover (8) onto the control box using four screws (7).
10.Turn on the power and gas supply.
50
PNEG-2091
VariFlame™ Heater
Summary of Contents for VariFlame VF-16-ONG
Page 4: ...NOTES 4 PNEG 2091 VariFlame Heater...
Page 28: ...Chapter 4 Installation Figure 4 6 VariFlame EDGE wiring diagram 28 Pneg 2091 VariFlame Heater...
Page 29: ...Chapter 4 Installation Figure 4 7 VariFlame EDGE schematic PNEG 2091 VariFlame Heater 29...
Page 30: ...Chapter 4 Installation Figure 4 8 Dipswitches 30 PNEG 2091 VariFlame Heater...
Page 31: ...NOTES PNEG 2091 VariFlame Heater 31...
Page 38: ...NOTES 38 PNEG 2091 VariFlame Heater...
Page 54: ...NOTES 54 PNEG 2091 VariFlame Heater...