Troubleshooting
Topics Covered in this Chapter
Troubleshooting
LED Meanings
• When the system light is “solid” red, there is an error currently present, and the Airflow or Gas Valve
error indicator lights will be flashing to determine the cause of the error.
• When the system light is “solid” green, the heater is running with no errors.
• When the system light is “flashing” green, there are no errors and the heater is awaiting a signal to
start.
• When the system light is “flashing” red, there was an error present that has self-corrected, and the
Airflow or Gas Valve error indicator lights will be flashing to determine the error cause.
• In order to reset the heater once an error has occurred, main power must be cycled. If the error per-
sists, corrective action must be taken.
Figure 7-1
VariFlame On-Off Controller
Item — Description
1 — System Light
— Red or Green light.
2 — Airflow Light
— Blue LED light only.
3 — Gas Valve Light
— Yellow LED light only.
4 — On-Off Switch
— Turns the power on and off to the controller.
PNEG-2091