Part No. 4801-5338 Rev 2-2015
Evolution 4000
19 of 86
Refer to Section 6.4.2 & 7.9.
When Mode=Off, those stages will not
be visible on the Stage Conditions
Screen.
STAGE CONDITIONS SCREEN EXAMPLE:
Refer to Section 7.13.
Refer to Section 6.4.3, 7.6, & 7.11.7.
Target: The desired temp. of the building.
Enter Tun: Fans enter Tunnel at set temp.
Exit Tun: Fans exit Tunnel at set temp.
N/A: The stage is not allowed to turn on with the current set conditions.
Off: The stage is currently OFF.
On: The stage is currently ON.
Timed: The stage is currently ON with a timer.
Refer to Section 7.12.
Refer to Section 6.4.1 & 7.5.
Refer to Section 6.4.1 & 7.5.
Refer to Section 6.4.3 & 7.6.
Refer to Section 7.9 and 7.11.1.
Refer to Section 7.11.2.
Refer to Section 7.11.3.
Refer to Section 7.11.4.
(1)Stage Properties
#
STATUS MODE
RTEMP
ON
OFF
TIME
1
On
Attic Open
<ACTIVE>
2
Off
Attic Close
<ACTIVE>
3
Off
Vent Open
<CLOSED>
4
On
Vent Close
<CLOSED>
5
Off
Tunnel 1 Open
<CLOSED>
6
On
Tunnel 1 Close
<CLOSED>
7
Off
Tunnel 2 Open
<CLOSED>
8
On
Tunnel 2 Close
<CLOSED>
9
Off
Natural 1 Open
<ACTIVE>
10
On
Natural 1 Close
<ACTIVE>
11
On
Light
Ramp
12
On
Light
Ramp
13
Off
Feed
Sch1
14
Off
Feed
Sch2
15
Off
Heat
86.0°
77.5° 79.0°
None
16
Off
Heat
86.0°
77.5° 79.0°
None
17
Off
Heat
86.0°
77.5° 79.0°
None
18
Off
Heat
86.0°
75.0° 77.0°
None
-----------
TARGET
80°
---------
19
Off
Cstir
86.0°
82.0° 81.0°
Min1
20
Off
Cstir
86.0°
82.0° 81.0°
21
Off
Cstir
86.0°
82.0° 81.0°
22
Off
CNeg
86.0°
82.5° 81.0°
23
Off
CNeg
86.0°
82.5° 81.0°
24
Off
CNeg
86.0°
83.0° 81.5°
25
On
CNegT
86.0°
83.0° 82.0°
26
On
CNegT
86.0°
84.0° 83.0°
27
On
CTUN
86.0°
84.5° 83.0°
28
On
CTUN
86.0°
85.0° 84.0°
29
On
CTUN
86.0°
86.0° 85.0°
30
Off
CTUN
86.0°
88.0° 86.0°
31
Off
CTUN
86.0°
90.0° 88.0°
-----------
MAXIMUM TUNNEL FANS
----------
32
Off
CEVAP
86.0°
92.0° 87.0°
Var
33
Off
CEVAP
86.0°
92.0° 87.0°
Var
34
Off
Off
35
Off
Off
36
Off
Off
37
Off
Off
38
Off
Off
39
Off
Off
40
Off
Off
U1
On
NAT CLOSE ---.-
90.0° CLOSED:No
U2
On
NAT CLOSE ---.-
90.0° CLOSED:No
U3
On
NAT CLOSE ---.-
90.0° CLOSED:No
U4
On
NAT CLOSE ---.-
90.0° CLOSED:No
U1
Off
NAT OPEN
---.-
92.0° CLOSED:No
U2
Off
NAT OPEN
---.-
92.0
CLOSED:No
U3
Off
NAT OPEN
---.-
92.0
CLOSED:No
U4
Off
NAT OPEN
---.-
92.0
CLOSED:No
---
On
Exit Tun
---.-
----
83.0
----
---
On
Enter Tun ---.-
86.0
----
----
Refer to Section 6.4.1, 7.5 & 7.8.
Refer to Section 7.11.6.
Maximum Tunnel Fans: The maximum number
of tunnel fans will be turning ON from this point
downward with hotter temperatures.
Refer to Section 7.11.5.