Part No. 4801-5338 Rev 2-2015
Evolution 4000
56 of 86
9.2
Voltage Selection Internal Wiring for the EV4000 Controller
WARNING!!
Ensure The
Internal Voltage
Selection Wiring Is
Connected As
Required BEFORE
Power Is Applied
To The Controller.
230 VAC
Wiring
115 VAC
Wiring
Jumper
Connection
Required
For
230 VAC
Power
Jumper
Connection
Not
Required
For
115 VAC
Power
The EV4000 controller is factory prewired for 240 VAC. For 115 VAC Power,
disconnect both the orange and yellow wires from the orange jumper then connect
the Yellow and Orange wires to the terminal block L1 & L2 as shown above.