G1 RO Series Specifications
NOTE Specifications for G1 RO 230V (international) are in
.
G1-2S G1-3S G1-4S G1-2L G1-3L G1-4L G1-1F G1-2F
Nominal Capacity, GPD [m³/hr]*
500
[0.08]
750
[0.12]
1000
[0.16]
1200
[0.19]
1700
[0.27]
2200
[0.35]
2000
[0.32]
4000
[0.63]
Dimensional, Series G1 Units
Width - in [mm]
34.5 [876]
38.5
[978]
34.5 [876]
38.5
[978]
34.5 [876]
Depth - in [mm]
8.7 [221]
Height - in [mm]
34.8 [884]
45.5 [1156]
Operating Weight, lb [kg]
81 [37]
92 [42]
96 [44]
88 [40]
103 [47]
111 [50]
97 [44]
129 [59]
Unit Connections
Inlet (Tube) - in.
1/2
Product (Tube) - in.
1/2
Concentrate (Tube) - in.
3/8
Electrical
Motor Horsepower, hp [kW]
0.333 [0.25]
0.75 [0.56]
Power Requirement (VAC/Hz/phase)
115/60/1
Full Load Current, amp (@115V)
8
12
Hydraulic - Prefilter
Housing Quantity
1
Cartridge Rating, micron
5
Cartridge Length - in [mm]
10 [254]
Hydraulic - RO
RO Housing Quantity
2
3
4
2
3
4
1
2
RO Element Quantity
2
3
4
2
3
4
1
2
RO Element Size - in
2.5x21
2.5x40
4x40
RO Array
1:1
1:1:1
1:1:1:1
1:1
1:1:1
1:1:1:1
1
1:1
Product Flow - gpm [L/min]*
0.35
[1.32]
0.52
[1.97]
0.69
[2.61]
0.83
[3.14]
1.18
[4.47]
1.53
[5.79]
1.40
[5.30]
2.8
[10.6]
Concentrate Flow - gpm [L/min]*
0.35
[1.32]
0.52
[1.97]
0.69
[2.61]
0.83
[3.14]
1.18
[4.47]
1.53
[5.79]
4.17
[15.78]
2.78
[10.52]
Required Inlet Feed Flow gpm [L/min]
0.7
[2.65]
1.04
[3.94]
1.38
[5.22]
1.66
[6.28]
2.36
[8.93]
3.06
[11.58]
5.56
[21.04]
5.56
[21.04]
Pump Flow @ 150 psi, gpm [Lmin]
1.6 [6.06]
2.7 [10.44]
3.1 [11.73]
5.6 [21.2]
Maximum Module Feed Pressure psig [kPa]
150 [1034]
Nominal Module Feed Pressure psig [kPa]†
100
[689]
103
[709.7]
104
[716.6]
96
[661.4]
97
[668.3]
101
[695.9]
95
[654.6]
101
[695.9]
Max. Product Pressure psig [kPa]
40 [275.6]
Inlet Pressure Min., dynamic psig [kPa]
20 [137.8]
Maximum, dynamic psig [kPa]
50 [344.5]
Operating Temp °F [°C]
33-100 [1-38]
Recovery (%)*
Design
50
50
50
50
50
50
25
50
Minimum
40
40
40
40
40
40
15
40
Salt Rejection, Nominal (%)
98
†Calculated using a 0.85 fouling factor
*Nominal capacity based on new RO membranes operating on a properly pretreated feed water of 500 ppm TDS as NaCl,
77 °F (25 °C), Silt Density Index (SDI) below 3, and supplying water to atmosphere. Productivity will vary depending on
the actual feed water quality and temperature.