Error Limits
Setting Error Limits
Limits can be set for various operating parameters. If these limits are exceeded, the GBE RO Controller will trigger an
error message and shut down the RO system. User intervention is required to restart the RO system. If the modem option
is installed, this error will be transmitted when the system calls in.
RUNNING
JAN-01-12 12:01P
1. From the default home screen, press
. The screen displays the main menu.
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
2. Press
to scroll to 4) SETUP.
3. Press
to select the SETUP menu.
4) FLUSH MODES
5) ACCESSORIES
6) DIAGNOSTICS
>7) ERROR LIMITS
4. Press
to select 7)ERROR LIMITS.
Error Limits Settings
Press
or
and then
to change the value if necessary.
Screen Display
Range
Procedure
MAX RECOVER%
90%
0–100
The system’s recovery changes as operating parameters fluctuate
and membranes age. Set this value to the maximum allowable re-
covery. As the recovery increases, product quality decreases (TDS
increases).
MIN RECOVER%
10%
0–100
Set this to trigger an alarm if the recovery falls below the setting. A
very low recovery can indicate membrane fouling or a mis-adjusted
system.
MAX IN TEMP
120F
0–200
This is the maximum allowable temperature for the system.
MIN IN TEMP
33F
33–100
This is the minimum allowable temperature for the system.
MAX TDS OUT
250
PPM
1–500
Select the highest total dissolved solids in the product water (low-
est product quality) accepted by the G1 or M2 RO. Product water
that exceeds the maximumTDS level will trigger an error condition,