Error Limits
59
Cat. No. 01021713
MAX PUMPTIME
0
Hours/Day
0–23
Specify the maximum number of hours per day that the pump is
to run. If the value is set to 0 then this feature is ignored. If the
value is non-zero then each day (at the time of the daily email) the
system checks to see if, within the past 24 hours, the pump run
time has exceeded the specified number of hours. If the number of
hours HAS EXCEEDED the specified limit, the system will continue
to operate, but the error flag corresponding to the maximum num-
ber of pump hours per day will be sent in the email message and
the message “Max Pump hrs/day” will show along with the “Prob-
lem Found” message on the home screen.
MIN N FLOW
0.00
GPM
0–250
Specify the minimum flow rate in gallons per minute at a normal-
ized temperature of 77°. If the flow rate drops below the minimum,
the GROC will display an error limit message.
NOTE If the MIN N FLOW value is left at zero, this error
level will be ignored, and it will not be displayed in
the Information screen.
STD PRESSURE
120
PSI
1–1000
If the minimum normalized flow setting is specified (any number
other than zero), then specify the standard pressure across the
membranes at the normalized temperature of 77° (p1-p2)/2
RUNNING
JAN-01-12 12:01P
QUAL FLUSH
5. Press
to return to the home screen. The screen displays any additional
modes in progress that are triggered by an error state. For example, the RO sys-
tem will have a quality flush if TDS exceeds the Max TDS Out.